Instruction Manual


4-12
IM 01R04B04-00E-E 8th edition March 01, 2011 -00
All Rights Reserved. Copyright © 2003, Rota Yokogawa

Remote type converter RCCF31 / RCCR31 are used with remote type detector RCCS3. To connect these
instruments use pair- / triple-twisted cable with overall shielding type Li2Y(st)+CY 3x2AWG24 + 1x3 AWG20
exclusive cable RCCY03. The maximum length is 300 m / 984 ft; 50 m/164 ft for FM-applications
Cross-sectional view of remote cable RCCY03:
For RCCY03 -1-L the cable is completely terminated.
For RCCY03 -0-L the termination set is attached and the customer has to terminate the cable by his own
.
The termination set contains:
- 6 x 20 mm 0.15 m shrink down plastic tube, d= 3.2 mm
- 2 x 20 mm 0.05 m shrink down plastic tube, d= 4.8 mm
- 18 conductor markers
- 12 terminal sleeves 0.25 mm
2
light blue
- 6 terminal sleeves 0.5 mm
2
orange
- 1 terminal sleeve 1.5 mm
2
For ATEX explosion proof application cable RCCY03-xLxxx /KS1 (blue color) is recommend
ed.
NOTE
Careful assembly of the cable is indispensable for correct connection between the detector and the
converter. This ensures good measuring results.
'BJ
1MBTUJDTIFBU
0VUFSTIJFME
8SBQ
"MVNJOJVNGPJM
$PSF
'JMMFS
*OOFSTIJFME
'BJ