Instruction Manual
4-5
IM 01R04B04-00E-E 8th edition March 01, 2011 -00
All Rights Reserved. Copyright © 2003, Rota Yokogawa
'BJ
1JQFGMBOHF
#PMU
/VU
(BTLFU
'MPXNFUFS'MBOHF
Clamp and gasket must be mounted to t into the groove of the ferrules of the pipe, tted to cover the taper
portion of the ferrule to the Coriolis owmeter.
The ferrules, clamps, gaskets are not included and must be provided on site.
F0306.ai
Ferrule
Gasket
Clamp
A stable zero is mandatory for a good mass ow measurement. Mechanical installation
stress and ow
noise inuence zero stability. Action has to be taken to avoid any generation
of sound.
Recommendations:
• Support the weight of the detector by soft coupling (silicon or other kind of rubber support.
•
Do not bend or stress the detector via the adjacent pipe. This is achieved by supporting
the pipe 10D or
more away from the detector.
• Pipe reduction or extension should be avoided directly before or after the meter.
• Avoid any control valves or orices or any other sound generator near the detector.