Instruction Manual
8-1
IM 01R04B04-00E-E 8th edition March 01, 2011 -00
All Rights Reserved. Copyright © 2003, Rota Yokogawa
The self check function displays instrument errors, warnings and alarms.
When an alarm or error occurs, the code (e.g. E-01) and the name (e.g. Frequency fault) appear on the
display during display mode, alternating with measuring value indication. This does not happen in parameter
setting mode.
The alarms, errors and warnings are written into history, see chapter 9.2.
The following table shows the possible alarms, warnings and error with the concerning inuences on outputs
and elds variables.
Alarm (A);
Warning
(W)
Error (E)
Name
Flow on Dis-
play
Density/Temp.
on Display
Totalizer on
Display
Analog
outputs
Frequ./Pulse-
outputs
Status outputs
*)
nc = no change, nd = not dened
A-01 MF 1 criteria nc nc nc nc
6)
Mass ow alm 1
*)
A-02 MF 2 criteria nc nc nc nc
6)
Mass ow alm 2
*)
A-03 VF 1 criteria nc nc nc nc
6)
Vol ow alm 1
*)
A-04 VF 2 criteria nc nc nc nc
6)
Vol ow alm 2
*)
A-05 Dens. 1 criteria nc nc nc nc
6)
Density alm 1
*)
A-06 Dens. 2 criteria nc nc nc nc
6)
Density alm 2
*)
A-07 Temp. 1 criteria nc nc nc nc
6)
Temp alm 1
*)
A-08 Temp. 2 criteria nc nc nc nc
6)
Temp alm 2
*)
A-09 Conc. 1 criteria nc nc nc nc
6)
Conc meas alm 1
*)
A-10 Conc. 2 criteria nc nc nc nc
6)
Conc meas alm 2
*)
A-11 Netow 1 crit. nc nc nc nc
6)
Net ow alm 1
*)
A-12 Netow 2 crit. nc nc nc nc
6)
Net ow alm 2
*)
A-13 Total thr exceed nc nc hold;continue
1)
nc
6)
Total switch
*)
A-14 Slug detection
MFL: meas.;
hold
4)
DEN: meas.;
hold
4)
nc nc
6)
Slug alarm
*)
A-15 Empty pipe det.
MFL: meas.;
hold
2)
nc nc nc
6)
Empty pipe alm
*)
A-16 Corrosion det. nc nc nc nc
6)
Corrosion alm
*)
W-01 Density low nc DEN: 0 kg/l
5)
nc nc nc nc
W-02 Fixed dens act. nc DEN: x value nc nc nc nc
W-03 Fixed temp act. nc TEMP: x value nc nc nc nc
W-04 Fixed MF active
MFL: x
value
+ act. zero
nc nc nc nc nc
W-05 Autozero running nc nc nc nc nc nc
W-06 AZ val error nc nc nc nc nc nc
W-07 AZ uct error nc nc nc nc nc nc
W-08 Sensor simul. nc nc nc nc nc nc
W-09 Fixed Prim Out nc nc nc 4mA nc nc
W-10 Prim Out sat. nc nc nc nc nc nc
W-11 Sec Out sat. nc nc nc nc nc nc
W-12 Tert Out sat. nc nc nc nc nc nc
W-13 Quart Out sat. nc nc nc nc nc nc
E-01 Frequency fault nd
Dens = nd
Temp = nc
hold 3,6mA;…
3) 6) 7)
E-02 Signal fault nd nc hold 3,6mA;…
3) 6) 7)
E-03 EEPROM fault nd nd hold 3,6mA;…
3) 6) 7)
E-04 CPU fault nd nd nd 3,6mA…
8)
nd nd
E-05 DSP fault nd nd hold 3,6mA…
8) 6) 7)
E-06 Sensor 1 fault nd
Dens = nd
Temp = nc
hold 3,6mA;…
3) 6) 7)
E-07 Sensor 2 fault nd nc hold 3,6mA;…
3) 6) 7)
E-08 Temp sens fault nc
Density = nd
Temp = 30°C
hold 3,6mA;…
3) 6) 7)
1)
Choice of “Total at alarm” (Detailed Setup / Totalizer)
2)
Choice of “Output after Empty pipe” (Detailed Setup / Empty pipe detect)
3)
Choice of “Analog 1/2 alarm out” (Detailed Setup / Cong Output) and NAMUR/NOT NAMUR (Measuring range)
4)
Choice of “After Slug” (Detailed Setup / Slug detection)
5)
Only if “Liquid” is selected (Detailed Setup / Liquid/gas selection)
6)
Choice of “Pulse 1 at alarm” or “Pulse 2 at alarm” (Detailed Setup / Pulse/Status out 1/2)
7)
Status outputs active if “All Errors” or “All Alarms & Errors” is selected (Detailed Setup / Pulse/Status out 1/2)
8)
Choice of jumper “Burn-out” (See chapter 8.7.9 Setting “Burn-out” Mode)
*) Status outputs acc. SO 1/2 function and SO 1/2 active mode