Instruction Manual


7-96
IM 01R04B04-00E-E 8th edition March 01, 2011 -00
All Rights Reserved. Copyright © 2003, Rota Yokogawa

 To set totalizer function.
Totalizer increments the forward ow if ow direction is forward or
the reverse ow if ow direction is reverse.
 Flex totalizer is available as a secondary total for mass, volume or net.
Select: 
If assignment is changed Flex totalizer will be set to zero, 
 will be set to default.
 When  is set to  or ,
the   can be selected.
When t is set to  or ,
the 
 can be selected.
 only for gas application.
 only for gas application or if Reference
density value is selected.
 Select: 
 For it


can be selected.
 only for gas application.
 only for gas application or if 
 is selected.
 For option /CST:
When  is set to ,
the  can be selected.
When t is set to ,
the 
can be selected.
For option /Cxx:
Selection depends from concentration unit.
 Select: 
 Set the caloric value of the medium with the unit Energy factor/
Heat of combust. unit.
The totalized energy of the medium can be indicated on display by
F-Total energy.
Heat of combust. unit  and can
be selected.
 Select: 
 A totalizer limit can be set only to the forward
totalizer selected in. If status output is set to 
, status output is set active, if the totalizer reaches this value.
Total switch is not active if set to 0.0.
 Select: 
Characteristic of totalizer selected in in case of the
 is active.
If  is selected forward and reverse totalising stops.
 Select: 
Enables or inhibits total reset.