Instruction Manual


7-93
IM 01R04B04-00E-E 8th edition March 01, 2011 -00
All Rights Reserved. Copyright © 2003, Rota Yokogawa


 To set the pulse/status output 2.
 Select: 
If Pulse is selected, Status out 2 (SO) is not available.
If  is selected, pulse parameters are not available.
 Select: 



Numbers may be displayed if selected via HART.
If  or  are selected, pulse
output only works at forward ow.
If  or  are selected, pulse
output only works at reverse ow.

To select the pulse output mass
or volume has to be selected.
If mass ow or volume ow is
selected the output delivers only
frequency.
Select: 

If  is 
or , only  can be selected.
If  is 
 or  only  can be selected.
 only for gas application.
 only for gas application or if Reference density
value is selected.
 The Pulse rate can be set according to the unit set in  
Maximum pulse rate is 2000 Hz.
 Select: 
The output levels depending on this parameter are shown on page 7-91.
 Select: 

 Select: 
If  is selected, in case of alarm the pulse output is stopped.
If  is selected, the pulse output keeps on measuring.
If  is selected, the pulse output keeps the value before entering the
alarm/error state.
NOTE