Online Device setup Set parameters for Rotamass (see below)
PV Display process value in engineering unit
PV AO Display analogue output in mA
Review Review parameters for Rotamass (see below)
Service Not open
Device
setup
Language English Sel
German
French
Russian
Process View d dev vars Mass o R
variables Volume o R
Dens R
Temp R
Conc meas R
Net o R
F-Totl ex R
R-Totl ex R
D-Totl ex R
F-Totl mass R
R-Totl mass R
D-Totl mass R
F-Totl vol R
R-Totl vol R
D-Totl vol R
F-Totl net R
R-Totl net R
D-Totl net R
F-Totl energy R
Velocity R
Drive Gain R
View Outputs Analog output 1 Analog 1 select R
PV R
PV AO R
% rnge R
Analog output 2 Analog 2 select R
SV R
SV AO R
% rnge R
Pulse/Status out 1 Pulse 1 select R
TV R
TV Freq R
SO 1 function R
SO 1 mode R
No function R