Owner manual

6-13
IM 04L41B01-17E
Specifications
1
2
3
4
5
6
App
Index
Register Description Supplementary Information Type Access Simultaneous
Access
Write Read
409512 Manual sampling start
or other action
Manual sampling: 0. Manual trigger: 1. Snapshot:
2.
INT16 W
410001 to
410002
Batch 1 lot number Valid range: 0 to 99999999 INT32_L R/W
410003 to
410020
Batch 1 batch number Up to 18 registers (up to 35 characters with '\0'
termination).
The batch number must be 32 characters or less.
STR36 R/W
410021 to
410050
(Reserved) batch 1 - - -
410051 to
410052
Batch 2 lot number Valid range: 0 to 99999999 INT32_L R/W
410053 to
410070
Batch 2 batch number Up to 18 registers (up to 35 characters with '\0'
termination).
The batch number must be 32 characters or less.
STR36 R/W
410071 to
410100
(Reserved) batch 2 - - -
410101 to
410102
Batch 3 lot number Valid range: 0 to 99999999 INT32_L R/W
410103 to
410120
Batch 3 batch number Up to 18 registers (up to 35 characters with '\0'
termination).
The batch number must be 32 characters or less.
STR36 R/W
410121 to
410150
(Reserved) batch 3 - - -
410151 to
410152
Batch 4 lot number Valid range: 0 to 99999999 INT32_L R/W
410153 to
410170
Batch 4 batch number Up to 18 registers (up to 35 characters with '\0'
termination).
The batch number must be 32 characters or less.
STR36 R/W
410171 to
410200
(Reserved) batch 4 - - -
410201 to
410202
Batch 5 lot number Valid range: 0 to 99999999 INT32_L R/W
410203 to
410220
Batch 5 batch number Up to 18 registers (up to 35 characters with '\0'
termination).
The batch number must be 32 characters or less.
STR36 R/W
410221 to
410250
(Reserved) batch 5 - - -
410251 to
410252
Batch 6 lot number Valid range: 0 to 99999999 INT32_L R/W
410253 to
410270
Batch 6 batch number Up to 18 registers (up to 35 characters with '\0'
termination).
The batch number must be 32 characters or less.
STR36 R/W
410271 to
410300
(Reserved) batch 6 - - -
410301 to
410302
Batch 7 lot number Valid range: 0 to 99999999 INT32_L R/W
410303 to
410320
Batch 7 batch number Up to 18 registers (up to 35 characters with '\0'
termination).
The batch number must be 32 characters or less.
STR36 R/W
410321 to
410350
(Reserved) batch 7 - - -
410351 to
410352
Batch 8 lot number Valid range: 0 to 99999999 INT32_L R/W
410353 to
410370
Batch 8 batch number Up to 18 registers (up to 35 characters with '\0'
termination).
The batch number must be 32 characters or less.
STR36 R/W
410371 to
410400
(Reserved) batch 8 - - -
6.3 Modbus Protocol Specifications