Setting Commands (/AS1)
To apply settings that you have changed using the setting commands, you need to save
the settings using the BE command.
Command
Name
Function Execution
Mode
Setting Connection Monitor
Connection
Page
Administrator User
SR Sets an input range S Yes No No 3-19
SO Sets a computing equation S Yes No No 3-20
ER Sets the range of an external input channel S Yes No No 3-20
TJ Sets memory sampling S Yes No No 3-21
SA Sets an alarm Ss Yes No No 3-21
SW Sets the trend interval and auto save interval S Yes No No 3-22
TI Sets the circular display offset time S Yes No No 3-22
TO Sets how the DX operates after one circular
display cycle
S Yes No No 3-23
TW Sets the secondary trend interval S Yes No No 3-23
TM Sets manual sampling S Yes No No 3-23
TE Sets sampling conditions for event data S Yes No No 3-23
SZ Sets a zone S Yes No No 3-23
SP Sets a partial expanded display S Yes No No 3-24
ST Sets a tag S Yes No No 3-24
SX Sets a display group (release number 2 or
earlier)
S Yes No No 3-24
SL Sets a trip line (release number 2 or earlier) S Yes No No 3-24
NX Sets a display group (release number 3 or later) S Yes No No 3-25
NL Sets a trip line (release number 3 or later) S Yes No No 3-25
SG Sets a message S Yes No No 3-25
TH Sets the directory on the external storage
medium for saving data
Ss Yes No No 3-25
TZ Sets a file header S Yes No No 3-26
TF Sets a data file name S Yes No No 3-26
SD Sets the date and time OSs Yes No No 3-26
TD Sets daylight saving time S Yes No No 3-26
TT Sets the trend display S Yes No No 3-26
SE Sets the line width and the number of grids to
use on the trend graph.
S Yes No No 3-27
TB Sets the bar graph display S Yes No No 3-27
SB Sets the bar graph for a channel S Yes No No 3-27
TN Sets a scale S Yes No No 3-27
SV Sets a measurement channel’s moving average S Yes No No 3-27
SC Sets a channel display color S Yes No No 3-27
TA Sets an alarm point mark S Yes No No 3-27
TG Sets a color scale band S Yes No No 3-28
SQ Sets the LCD brightness and the screen
backlight saver
S Yes No No 3-28
TC Sets the background color S Yes No No 3-28
TP Sets automatic display group switching S Yes No No 3-28
NF Sets the favorite key operation. S Yes No No 3-28
TR Sets the automatic switching back to default
display
S Yes No No 3-28
TQ Sets a timer S Yes No No 3-28
TK Sets a match time timer S Yes No No 3-29
TU Sets an event action S Yes No No 3-29
SK Sets a constant S Yes No No 3-31
SI Sets the rolling average function of a
computation channel
S Yes No No 3-31
SJ Sets a TLOG timer S Yes No No 3-31
TX Sets the ancillary operation of the start key S Yes No No 3-32
BH Sets a batch text field S Yes No No 3-32
EH Sets calibration correction Ss Yes No No 3-32
BD Sets an alarm delay Ss Yes No No 3-32
NC Sets a comment text field S Yes No No 3-33
NB Sets a comment text block S Yes No No 3-33
3.2 A List of Commands