Manual

IM 01R01B30-00E-E 5th edition January 01, 2013 -00
<7. TECHNICAL DATA>
7- 5
All Rights Reserved. Copyright © 2003, Rota Yokogawa
OPTIONS
Options Option
code
Description Restriction
Indicator /A12
/A29
/A30
US- engineering units
M12- connector acc. IEC 61076-2-101 (in preparation)
M12- connector with plug connector acc. IEC 61076-2-101 (in prepa-
ration)
Only for indicator E
Only for indicator E or T with limit switches
Only for indicator E or T with limit switches
Marking /B1
/B4
/B8
/B10
/BG
/BD
Tag plate (SS) xed by wire and customer specied tag number on
scale
Neutral version
Customer provided marking on label
Percent scale
With customer specied tag number on scale
Dual Scale
Plate 12 x 40 mm; max. 45 digits
Not with Ex-proof type
Max. 45 digits
Adjustment only possible for 1 uid
Limit switches /K1
/K2
/K3
/K6
/K7
/K8
/K9
/K10
MIN- contact
MAX- contact
MIN-MAX- contact, MIN-MIN- contact, MAX-MAX- contact
MIN- contact “Fail safe” version
MAX- contact “Fail safe” version
MIN-MAX- contact “Fail safe” version
MIN-MIN- contact “Fail safe” version
MAX-MAX- contact “Fail safe” version
Only for indicator T
Only for indicator T
Only for indicator T
Only for indicator T
Pulse output /CP Pulse output, acc. EN 60947-5-6 (NAMUR) Only for indicator E; not with limit switches
Hazardous area
approvals
/KS1
/KS2
/KS3
/KN1
/ES1
/ES3
/FS1
/CS1
/NS1
ATEX intrinsically safe „ia“
ATEX gas and dust proof limit switches, category 2G 1D
ATEX intrinsically safe „ic“
ATEX category 3G „nL“ / 3D
IECEx intrinsically safe „ia“
IECEx intrinsically safe „ic“
FM intrinsically safe / non incendive limit switches (USA)
CSA intrinsically safe / non incendive limit switches (Canada)
NEPSI approval (China)
Not for indicator T without limit switches
Only for indicator T with limit switches
Not for indicator T without limit switches
Not for indicator T without limit switches
Not for indicator T without limit switches
For indicator T only with limit switches
For indicator T only with limit switches; limit switches
only /K1, /K2, /K3, only in combination with power
supply /WxA or /WxB
Not for indicator T without limit switches
Test and certicates /H1
/PP
/P2
/P3
/P6
/PM1
/PM4
/PM5
Oil + fat free for wetted surfaces
Pressure test report measuring system
Certicate of Compliance with the order acc. to EN 10204: 2004- 2.1
As /P2 +Test report acc. to EN 10204: 2004- 2.2
Material certicate acc. to EN 10204: 2004- 3.1
PAMI test (1 test point : metering tube)
PAMI test (4 test points : metering tube, connection heads, sealing plug)
PAMI test (5 test points : metering tube, connection pieces, slip on anges)
Not for /R1 and /R3
Only for tube, connection heads, screw sealing plug
Only for models with valve
Only for models with process connection D4, A1, A2
Gost approval /QR1
/QR2
/QR3
Primary Calibration and Test Conrmation valid in Russia
Primary Calibration and Test Conrmation valid in Kazakhstan
Primary Calibration and Test Conrmation valid in Uzbekistan
See page 4
See page 4
See page 4
Controller /R1
/R3
Pre pressure controller 1.4571 (only with valve in inlet; for gas
with
variable pre pressure and liquids with variable pre and back pressure)
Back pressure controller 1.4571 (only with valve in outlet; for gas
with variable back pressure)
Only for process connection R3, T3, C3, W3, P1;
only with valve
Only for process connection R3, T3, C3, W3, P1;
only with valve
Delivery to Korea /KC With KC-mark for Korea
Power supply for
electronic transmitter
/UT RN221N-B1, 20 ... 250V DC/AC, Ex i Only for indicator E
Power supply
for limit switches
(transmitter relay)
/W1A
/W1B
/W2A
/W2B
/W2E
/W2F
/W4A
/W4B
/W4E
/W4F
KFA5-SR2-Ex1.W / 115 V AC, 1 channel
KFA5-SR2-Ex2.W / 115 V AC, 2 channel
KFA6-SR2-Ex1.W / 230 V AC, 1 channel
KFA6-SR2-Ex2.W / 230 V AC, 2 channel
KHA6-SH-Ex1 / 115/230 V AC, 1 channel, Fail Safe
2x KHA6-SH-Ex1 / 115/230 V AC, 1 channel, Fail Safe
KFD2-SR2-Ex1.W / 24 V DC, 1 channel
KFD2-SR2-Ex2.W / 24 V DC, 2 channel
KFD2-SH-Ex1 / 24 V DC, 1 channel, Fail Safe
2x KFD2-SH-Ex1 / 24 V DC, 1 channel, Fail Safe
Only for limit switches /K1, /K2, /K3 or /CP
Only for limit switches /K1, /K2, /K3
Only for limit switches /K1, /K2, /K3 or /CP
Only for limit switches /K1, /K2, /K3
Only for limit switches /K6, /K7
Only for limit switches /K8, /K9, /K10
Only for limit switches /K1, /K2, /K3 or /CP
Only for limit switches /K1, /K2, /K3
Only for limit switches /K6, /K7
Only for limit switches /K8, /K9, /K10
Instruction manuals /IEn
/IDn
/IFn
Quantity of instruction manuals in English
Quantity of instruction manuals in German
Quantity of instruction manuals in French
n = 1 to 9 selectable *)
n = 1 to 9 selectable *)
n = 1 to 9 selectable *)
Special order /Z Special design must be specication on extra sheet
*) if no instruction manual is selected, only a DVD with instruction manuals is shipped with the owmeter