User Manual

5-12
IM 04P01B01-17E
Status Information
The IS command is used to output the data.
The operation status of the recorder is output
For details on the status information, see section 6.2, “The Bit Structure of the Status
Information.”
Syntax
EACRLF
ddd.ccc.bbb.aaaCRLF
ENCRLF
aaa
Status information 1 (000 to 255)
bbb
Status information 2 (000 to 255)
ccc
Status information 3 (000 to 255)
ddd
Status information 4 (000 to 255)
Example
EA
000.000.032.000
EN
User Information
The FU command is used to output the data.
User name, user level, and other information are output.
Syntax
EACRLF
p_l_uuu···uCRLF
ENCRLF
p
Physical layer
E: Ethernet
S: RS-422A/485
l
User level
A: Administrator
U: User
uuu···u
User name (up to 16 characters)
_
Space
Example
EA
E A admin
EN