User Manual
Commands
1
2
3
4
5
6
App
Index
IM 04P01B01-17E
4-23
•  On models with the computation function 
(/M1 option), computation channels can be 
specified.
UB  Sets the display mode of the bar 
graph.
Syntax
  UB p1,p2
<terminator>
p1
  Channel number
p2
  Bar graph display mode
NORMAL
  The reference position is set to the 
smaller of the two values, leftmost 
value and rightmost value.
CENTER
  The reference position is set to the 
50% position.
Query
  UB[p1]?
Example
  Display channel 01 using a bar graph with the 
reference position set to the 50% position.
UB01,CENTER
Description
 On models with the computation function (/M1 
option), computation channels can be specified.
UI  Sets whether to use moving 
average (dot model).
Syntax
  UI p1
<terminator>
p1
  Use/Not use moving average (USE, NOT)
Query
  UI?
Example  Use moving average.
UIUSE
UJ  Sets whether to use the input 
filter (pen model).
Syntax
  UJ p1
<terminator>
p1
  Use/Not use the input filter (USE, NOT)
Query
  UJ?
Example  Use the input filter.
UJUSE
UK  Sets whether to use of partial 
expanded recording.
Syntax
  UK p1
<terminator>
p1
  Use/Not use partial expanded recording 
(USE, NOT)
Query
  UK?
Example  Use partial expanded recording.
UKUSE
UL  Selects the display/printout 
language.
Syntax
  UL p1
<terminator>
p1
  Language (ENGLISH, JAP
ANESE, 
GERMAN, FRENCH)
Query
  UL?
Example
  Use English.
ULENGLISH
XN  Selects the date format.
Syntax
  XN p1
<terminator>
p1
  Date format for displaying and printing
Y/M/D
  (example) 2005/08/31
M/D/Y
  (example) 08/31/2005
D/M/Y
  (example) 31/08/2005
D.M.Y
  (example) 31.08.2005
M.D.Y
  (example) 
Aug.31.2005
Query
  XN?
Example
  Set to the “2005/08/31” format.
XNY/M/D
Description
 This setting applies to the format of the date 
shown on the display and the date printed on the 
periodic printout, manual printout, alarm printout, 
message printout, recording start printout, new 
chart speed printout, and start printout and end 
printout (header printout (/BT1 option)).
Note
How this setting applies to the time printout format of the alarm 
printout, message printout, recording start printout, and new chart 
speed printout: The setting specifies the format of the “M/D” and 
“Y/M/D” section when the time printout format is set to “M/D H:M,” 
“M/D H:M:S,” or “Y/M/D H:M:S.”
XT  Selects the temperature unit.
Syntax
  XT p1
<terminator>
p1
  T
emperature unit
C
  °C
F
  °F
Query
  XT?
Example
  Use °F
.
XTF
UF  Sets whether to use the extended 
functions.
Syntax
  UF p1,p2,p3,p4,p5
<terminator>
p1
  Bias function (USE, NOT)
p2
  Square root low-cut function (USE, NOT)
p3
  1-5V input low-cut function (USE, NOT)
p4
  Alarm delay function (USE, NOT)
p5
  Calibration correction function (USE, NOT)
(/CC1 option). This cannot be used with the 
bias.
Query
  UF? 
Example
  Use the calibration correction extended function. 
The bias function is not used.
UFNOT,USE,USE,USE,USE
Description
 •
  The input of
fset is set using the VB command.
•
  The low-cut function is set using the SR 
command.
•
  The delay alarm is set using the SA
 and BD 
commands.
4.5 Basic Setting Commands