User Manual

Commands
1
2
3
4
5
6
App
Index
IM 04P01B01-17E
4-23
On models with the computation function
(/M1 option), computation channels can be
specified.
UB Sets the display mode of the bar
graph.
Syntax
UB p1,p2
<terminator>
p1
Channel number
p2
Bar graph display mode
NORMAL
The reference position is set to the
smaller of the two values, leftmost
value and rightmost value.
CENTER
The reference position is set to the
50% position.
Query
UB[p1]?
Example
Display channel 01 using a bar graph with the
reference position set to the 50% position.
UB01,CENTER
Description
On models with the computation function (/M1
option), computation channels can be specified.
UI Sets whether to use moving
average (dot model).
Syntax
UI p1
<terminator>
p1
Use/Not use moving average (USE, NOT)
Query
UI?
Example Use moving average.
UIUSE
UJ Sets whether to use the input
filter (pen model).
Syntax
UJ p1
<terminator>
p1
Use/Not use the input filter (USE, NOT)
Query
UJ?
Example Use the input filter.
UJUSE
UK Sets whether to use of partial
expanded recording.
Syntax
UK p1
<terminator>
p1
Use/Not use partial expanded recording
(USE, NOT)
Query
UK?
Example Use partial expanded recording.
UKUSE
UL Selects the display/printout
language.
Syntax
UL p1
<terminator>
p1
Language (ENGLISH, JAP
ANESE,
GERMAN, FRENCH)
Query
UL?
Example
Use English.
ULENGLISH
XN Selects the date format.
Syntax
XN p1
<terminator>
p1
Date format for displaying and printing
Y/M/D
(example) 2005/08/31
M/D/Y
(example) 08/31/2005
D/M/Y
(example) 31/08/2005
D.M.Y
(example) 31.08.2005
M.D.Y
(example)
Aug.31.2005
Query
XN?
Example
Set to the “2005/08/31” format.
XNY/M/D
Description
This setting applies to the format of the date
shown on the display and the date printed on the
periodic printout, manual printout, alarm printout,
message printout, recording start printout, new
chart speed printout, and start printout and end
printout (header printout (/BT1 option)).
Note
How this setting applies to the time printout format of the alarm
printout, message printout, recording start printout, and new chart
speed printout: The setting specifies the format of the “M/D” and
“Y/M/D” section when the time printout format is set to “M/D H:M,”
“M/D H:M:S,” or “Y/M/D H:M:S.”
XT Selects the temperature unit.
Syntax
XT p1
<terminator>
p1
T
emperature unit
C
°C
F
°F
Query
XT?
Example
Use °F
.
XTF
UF Sets whether to use the extended
functions.
Syntax
UF p1,p2,p3,p4,p5
<terminator>
p1
Bias function (USE, NOT)
p2
Square root low-cut function (USE, NOT)
p3
1-5V input low-cut function (USE, NOT)
p4
Alarm delay function (USE, NOT)
p5
Calibration correction function (USE, NOT)
(/CC1 option). This cannot be used with the
bias.
Query
UF?
Example
Use the calibration correction extended function.
The bias function is not used.
UFNOT,USE,USE,USE,USE
Description
The input of
fset is set using the VB command.
The low-cut function is set using the SR
command.
The delay alarm is set using the SA
and BD
commands.
4.5 Basic Setting Commands