User Manual
4-4
IM 04P01B01-17E
Basic Setting Commands
Note
•  The settings that are returned in response to a query in the basic setting mode will contain 
the new settings even if they are not saved.
•  In order to activate the settings that are changed using the basic setting commands, the 
settings must be saved using the YE or XE command.
•  If the settings are saved with the XE command, communication is not dropped. If saved 
with the XE command, the settings that are changed using the YS/YB/YA/YN/YD/YQ/YK 
command are activated after power-cycling the recorder.
•  When the YE command is executed, communication is dropped. The response to the YE 
command is not returned.
•  The following settings cannot be changed.
  Key lock, enabling/disabling of the customized menu function, user registration for Ethernet 
communication.
Command 
Name
Function Execution Mode Administrator User Page 
XA
Sets alarm related settings. Basic Setting mode Yes No 4-20
XI
Sets the A/D integral time. Basic Setting mode Yes No 4-21
XB
Sets the burnout detection. Basic Setting mode Yes No 4-21
XJ
Sets the RJC. Basic Setting mode Yes No 4-21
UC
Changes the dot color (dot model). Basic Setting mode Yes No 4-21
UO
Sets the pen offset compensation (pen model). Basic Setting mode Yes No 4-22
UP
Sets the items to be printed. Basic Setting mode Yes No 4-22
UR
Sets the periodic printout interval. Basic Setting mode Yes No 4-22
UM
Sets the types of report data that are output to the 
periodic printout.
Basic Setting mode Yes No 4-22
UB
Sets the display mode of the bar graph. Basic Setting mode Yes No 4-23
UI
Sets whether to use moving average (dot model). Basic Setting mode Yes No 4-23
UJ
Sets whether to use the input filter (pen model). Basic Setting mode Yes No 4-23
UK
Sets whether to use of partial expanded recording. Basic Setting mode Yes No 4-23
UL
Selects the display/printout language. Basic Setting mode Yes No 4-23
XN
Selects the date format. Basic Setting mode Yes No 4-23
XT
Selects the temperature unit. Basic Setting mode Yes No 4-23
UF
Sets whether to use the extended functions. Basic Setting mode Yes No 4-23
UT
Selects the time printout format. Basic Setting mode Yes No 4-24
XR
Sets the remote control input (/R1 option). Basic Setting mode Yes No 4-24
YS
Sets the RS-422A/485 interface (/C3 option). Basic Setting mode Yes No 4-24
XQ
Sets the TLOG timer (/M1 option). Basic Setting mode Yes No 4-24
UN
Changes the assignment of channels to the recording 
pen (pen model, /M1 option).
Basic Setting mode Yes No 4-25
US
Sets the computation error procedure (/M1 option). Basic Setting mode Yes No 4-25
YB
Sets the host name and domain name (/C7 option). Basic Setting mode Yes No 4-25
YA
Sets the IP address (/C7 option). Basic Setting mode Yes No 4-25
YN
Sets the DNS (/C7 option). Basic Setting mode Yes No 4-25
YD
Sets whether to use the login function via communication 
(/C7 option).
Basic Setting mode Yes No 4-26
YQ
Sets the communication timeout (/C7 option) Basic Setting mode Yes No 4-26
YK
Sets keepalive (/C7 option). Basic Setting mode Yes No 4-26
UQ
Sets the calibration correction mode and the number of 
set points (/CC1 option).
Basic Setting mode Yes No 4-26
UA
Sets the record position. Basic Setting mode Yes No 4-26
UG
Sets the Setting mode menu selection. Basic Setting mode Yes No 4-27
UH
Sets the FUNC key menu selection. Basic Setting mode Yes No 4-27
UE
Selects enable/disable for Start printout/End printout 
and message format (/BT1 option).
Basic Setting mode Yes No 4-27
YE
Exits from Basic Setting mode. Basic Setting mode Yes No 4-27
XE
Exits from Basic Setting mode. Basic Setting mode Yes No 4-27
  Yes: Command usable
  No: Command not usable
4.2 A List of Commands