Setup Item Pen/Dot Selectable Range or Selections Default Value
Personalize > Add function > Bias - Not/Use Not
Personalize > Add function >
SQRT low-cut - Not/Use Use
Personalize > Add function > 1-5V low-cut - Not/Use Not
Personalize > Add function > Alarm delay - Not/Use Not
Personalize > Add function > Calibration - Not/Use Use
Personalize > Time print > Alarm - HH:MM, HH:MM:SS, M/D H:M, M/D H:M:S,
YMD H:M:S
HH:MM
Personalize > Time print > Message - HH:MM, HH:MM:SS, M/D H:M, M/D H:M:S,
YMD H:M:S, None
HH:MM
Personalize > Time print > RCD On - HH:MM, HH:MM:SS, M/D H:M, M/D H:M:S,
YMD H:M:S
HH:MM
Personalize > Time print > C.Speed - HH:MM, HH:MM:SS, M/D H:M, M/D H:M:S,
YMD H:M:S
HH:MM
Setting initialization
Initialize > Mode - Setup+Set/Set Setup+Set
Initialize > Mode > Are you sure? - No/Yes No
Remote (/R1 option)
Remote > Remote No. - 1/2/3/4/5 1
Remote > Remote No. > No. - Record On Off /Chart speed/Time adjust/
Math start stop (/M1)/Math reset (/M1)/
Manual print/Alarm ACK/Message1/Message2/
Message3/Message4/Message5/Priority
R_RCD (/BT1)/BatchCMT switch (/BT1)/None
(/M1, /BT1: option)
Record On/Off
Math (/M1 option)
Math > Timer (TLOG) > Timer No. - 1/2 1
Math > Timer (TLOG) > Mode - Off/Relative/Absolute Absolute
Math > Timer (TLOG) > Interval (Relative) - 10 min to 24 h (1 min steps) 01:00
Math > Timer (TLOG) > Interval (Absolute) - 10min/12min/15min/20min/30min/1h/2h/3h/4h/
6h/8h/12h/24h
1h
Math > Timer (TLOG) > Ref. Time - Hour 0 to 23 (1 hour steps) 00:00
Math > Timer (TLOG) > Reset - On/Off On
Math > Timer (TLOG) > Print - On/Off On
Math > Color > Channel Dot Model 0A/0B/0C/0D/0E/0F/0G/0J/0K/0M/0N/0P 0A
Math > Color > Color Dot Model Purple/Red/Green/Blue/Brown/Black Purple: 0A/0G
Red: 0B/0J
Green: 0C/0K
Blue: 0D/0M
Brown: 0E/0N
Black: 0F/0P
Math > Output pen > Pen←CH Pen Model Pen: 1 to 4, Channel: 01 to 04/0A to 0J
1pen: 01, 2pen: 02
,
3pen: 03, 4pen: 04
Math > Print2 > CH - 0A/0B/0C/0D/0E/0F/0G/0J/0K/0M/0N/0P 0A
Math > Print2 > Mode - AVE/MIX/SUM/MIN/MAX/INST AVE
Math > Print2 > SUM scale - Off, /s, /min, /h, /day Off
Math > Bar graph > CH - 0A/0B/0C/0D/0E/0F/0G/0J/0K/0M/0N/0P 0A
Math > Bar graph > Graph - Normal/Center Normal
Math > Error data > Error - +Over/–Over +Over
Math > Error data > Over - Skip/Limit Skip
RS-422/485 (/C3 option)
RS-422/485 > Address - 1 to 32 1
RS-422/485 > Baud rate - 1200/2400/4800/9600/19200/38400 9600
RS-422/485 > Data length - 7/8 8
RS-422/485 > parity - Odd/Even/None Even
RS-422/485 > Protocol - NORMAL/MODBUS NORMAL
Ethernet (/C7 option)
Ethernet > Host > Host - 64 characters or less Blank
Ethernet > Host > Domain - 64 characters or less Blank
Ethernet > Local IP > A - IP address 0.0.0.0
Ethernet > Local IP > M - IP address (Subnet mask) 0.0.0.0
Ethernet > Local IP > G - IP address (Default gateway) 0.0.0.0
Ethernet > DNS > DNS - On/Off Off
Ethernet > DNS > P - IP address (Primary DNS sever) 0.0.0.0