User Manual
46
IM 04P01B01-02E 
Changing the Displayed Information
Different display types can be registered to screens 01 to 15. As an example, the procedure 
of assigning 1-channel digital display (tag display) to screen 02 is explained below.
1.
  Hold the 
MENU
1
 key for 3 seconds to show the data display setup screen.
Selecting the Screen Number
2.
  Press the   key to select screen number 02 and then press the   key.
Screen No.=02
Displays the current display type name.
  A sample screen of the display type appears. A section of the display blinks to 
indicate that this is a data display setup screen.
Selecting the Display Type
3.
  Press the   key to switch the display. Select the TAG001A (Tag_1CH digital) 
display and then press the 
 key.
TAG001A
 200.0 mV
4.
  Press the   key to set the channel switching interval and then press the   key.
Interval:   Sets the channel switching interval. Select the interval from 
1 s, 2 s, 3 s, 4 s, 5 s, and manual.
Auto1s, Auto2s, Auto3s, Auto4s, Auto5s:
  Switches the displayed channel at the specied time interval.
Manual:
  Switch the displayed channel using a key (
CH UP
).
Interval=Auto2s
5.
  When the Setting complete screen appears, the new setting is applied.
Screen No.02
Setting complete
Press the   key to register display types to other screens.
Hold the 
MENU
1
 key down for 3 seconds to exit from the data display setup screen.
Display Types
Display types listed below are available besides the types on previous page.
1CH digital display
2CH digital display
4CH digital display
6CH digital display 
(Dot model)
4CH bargraph display (Pen model)
2CH digital + 2CH bargraph display
6CH bargraph display 
(Dot model)
1CH digital + 4CH bargraph display (Pen model)
1H3000.0ABC
1H-1999.9ABCDEF
2L 2000.0PQRSTU
999.9 999.9 999.9
999.9 999.9 999.9
1H3000.0 1H3000.0
3H3000.0 4H3000.0
1H-1999.9ABCDEF
1H3000.0 2L-999.9
Tag_1CH digital display
DI/DO display
Lights out
No display.
No display type is registered. Skips the screen 
during screen switching.
abcdefg
H-1999.9ABCDEF
Switches the displayed contents every 
3 seconds. Displays number of measurement 
inputs, optional functions, version number, etc.
System display
100mm Dot Model
Analog:6
Tag
Tag_1CH digital + 1CH bargraph display Tag_1CH digital + 1CH bargraph display
(Pen model)
Tag_2CH digital display
Skip
abcdefgH 200.0mV
jkmnpqr 200.0mV
Multiple
 display
Remote control inputs
Alarm output relays
abcdefgH
-1
999.9ABC
abcdefgH
-1
999.9ABC
1H-1999.9ABCDEF
05/08/31 11:26:37
Batch name
 display
Batch Number-0001
(Different screens can be assigned to top and 
bottom sections)
*  When the key or key is pressed while holding down the SHIFT key, the operation is reversed as 
  when the respective key is pressed by itself.
Recording/Displaying Data