Owner manual

21
IM MX100-02E
Wiring the Digital Input Modules (-D05, -D24)
Note
On the digital input modules, the negative terminals and empty terminals of all channels are
shorted internally.
When the screw terminal plate (model 772080) is connected to the digital input module, the
terminal arrangement differs from that of clamp terminals, therefore wire according to the
markings on the terminal cover.
Wiring with the -D05 Option
• Transistor input
• Contact input
• 5V logic input
Main Input Specifications (-D05)
Input type: DI (non-voltage contact, open collector, and 5 V logic)
Input format: Pull-up at approximately 5 V/approximately 5 kΩ, common
electric potential between channels
Min. detection pulse width:
Twice the sampling interval or more
Input threshold level:
Non-voltage contact, open collector: ON
at 100 or less and
OFF at 100 kΩ or greater
5-V logic: OFF at 1 V or less and ON at 3 V or greater
Contact/transistor rating:
Conta
ct with a rating of 15 VDC or greater and 30 mA or
greater
Vce and Ic are transistors
with ratings of 15 VDC or more, and
30 mA or more, respectively.
Terminal type: Clamp
Applicable wire size: 0.14 to 1.5 mm
2
(AWG26 to 16)
Wiring with the -D24 Option
24V
• 24 V logic input
Main Input Specifications (-D24)
Input type: DI (24 V logic)
Input format: Common potential between ch
Min. detection pulse width:
Twice the sampling interval or more
Input threshold level: 24 V logic: OFF at 6 V or less and ON at 16 V or greater
Terminal type: Clamp
Applicable wire size:
0.14 to 1.5 mm
2
(AWG26 to 16)
Signal Wiring of the MX100