These 33 VCRs are factory-set as shown in Table 5.5.
Table 5.5 VCR List
5.5.2 Function Block Execution Control
According to the instructions given in Section 5.3, set the execution cycle of the function blocks and
schedule of execution.
Sub-
index
Parameter Description
6 FasDllMaxConfirm
DelayOnData
For request of data, a maximum wait time for the called party's
response is set in ms. Typical value is 60 seconds (60000).
7 FasDllMaxDlsduSize
Specifies maximum DL Service Data unit Size (DLSDU). Set 256
for Server and Trend VCR, and 64 for other VCRs.
8 FasDllResidual
ActivitySupported
Specifies whether connection is monitored. Set TRUE (0xff) for
Server. This parameter is not used for other communication.
9 FasDllTimelinessClass
Not used for the AV550G.
10 FasDllPublisherTime
WindowSize
Not used for the AV550G.
11 FasDllPublisher
SynchronizaingDlcep
Not used for the AV550G.
T0504-2.ai
13 FasDllSubscriber
SynchronizationDlcep
Not used for the AV550G.
14 FmsVfdId
Sets VFD for the AV550G to be used.
0x1: System/network management VFD
0x1234: Function block VFD
15 FmsMaxOutstanding
ServiceCalling
Set 0 to Server. It is not used for other applications.
16 FmsMaxOutstanding
ServiceCalled
Set 1 to Server. It is not used for other applications.
17 FmsFeatures
Supported
Indicates the type of services in the application layer. In the AV550G,
it is automatically set according to specific applications.
12 FasDllSubscriberTime
WindowSize
Not used for the AV550G.
T0505.ai
Index
(SM)
VCR
Number
Factory Setting
293 For system management (Fixed)1
294 Server (LocalAddr = 0xF3)2
295 Server (LocalAddr = 0xF4)3
296 Server (LocalAddr = 0xF7)4
297 Trend Source (LocalAddr = 0x07,
Remote Address=0x111)
5
298 Publisher (LocalAddr = 0x20)6
299
Alert Source (LocalAddr = 0x07,
Remote Address=0x110)
7
300 Server (LocalAddr = 0xF9)8
9 to 33
Not set
301 to 325