Manual

<3.Installation>
3-4
IM 11M10B01-01E
3.2.3 MountingActivatedCarbonFilter
Mountthelteronapanelorwall.ToxthelterwithM5screws.Whenreplacealterpack,200mm
or more of maintenance space is necessary. If necessary, the piping connection should be removable.
(Rc1/4 or 1/4NPT)
(Rc1/4 or 1/4NPT)
110
K9643KH: Rc1/4
K9643KJ: 1/4NPT
± 0.5
± 0.5
Unit: mm
Sample gas outlet
2-Ф6.5
holes
2-M5
screws
Mark “A”
In case of
K9643KJ
Activated carbon filter of
option code “/A”
Sample gas inlet
Fixing holes
more than 200
Maintenance space
The filter holder including
piping connection can be
moved upward to replace
a filter element.
more than
200
Maintenance space
The filter holder including
piping connection can be
moved downward to
replace a filter element.
110
150 130
47
29.5
25
15
10
(157)
35
35
60
47
Figure3.3 MountingActivatedCarbonFilter
NOTE
Theactivatedcarbonlterusedinthisequipmenthavelimitedlife,andperiodicmaintenanceor
replacement will be required. Install this equipment in an accessible location to facilitate maintenance.
Maintenanceconditionsvarydependingonthegasconditions.Replacementintervalsforthelterand
activated carbon should be determined in accordance with the operating conditions.
•Activatedcarbonlterlifeisabout50hours.(ifmeasuredgascontainsisopropylalcoholof
concentration500ppm,andowis500ml/min.)
•Incaseofusingthebuilt-inpumporwiththeaspirator,theactivatedcarbonlterlifeisabout25
hours.