User Manual
3
IM 77J01S11-01E 2nd Edition Mar, 02. 2012-00
4. DESCRIPTION OF FRONT PANEL
4.1 Front Panel
The communications connector in the front panel is used for
setting up parameters through a PC (VJ77 PC-based Parameters
Setting Tool) or the Handy Terminal.
Connector for
communication
4.2 Connector for Communication
Use the connector for communication when setting the
parameters using a PC (VJ77 Parameters Setting Tool) or the
Handy Terminal
How to connect with the setting tool
Modular jack conversion
adapter (E9786WH)
[Provided with VJ77]
JHT200
Handy Terminal
JUXTA communication cable
with 5-pin connector (F9182EE)
[Provided with VJ77 and JHT200]
Dedicated adapter (E9789HA)
[Provided with VJ77]
PC which is installed
with the VJ77
Dedicated cable (E9786WK)
[Provided with VJ77]
• Use the VJ77 of version R1.04 or later.
• The modular jack conversion adapter does not come with the
JHT200 Handy Terminal. It is sold separately.
5. SETTING PARAMETERS
Set the parameters using a PC (VJ77 Parameter Setting Tool) or
the Handy Terminal. Refer to “6. LIST OF PARAMETERS” in this
manual and the User’s Manual for VJ77 PC-based Parameters
Setting Tool (IM 77J01J77-01E) or the User’s Manual for JHT200
Handy Terminal (IM JF81-02E). Parameters are indicated inside
the [ ].
Setting High Selector/Low Selector
• Set the high selector or low selector in the xed constant
[H01:CONST].
• High selector: H01=100.0
• Low selector: H01=0.000
Note
Do not change the parameter set value of the other
than above.
6. LIST OF PARAMETERS
Parameter Display Item
MODEL Model
TAG NO Tag No.
SELF CHK Self-check result
A DISPLAY1 Display 1
*1
A01 INPUT1 Input value 1
A02 INPUT2 Input value 2
A05 OUTPUT1 Output value 1
A06 OUTPUT2 Output value 2
A11 T1 Temporary memory 1
A12 T2 Temporary memory 2
A13 T3 Temporary memory 3
A14 T4 Temporary memory 4
A15 DI Digital input
A16 DO Digital output
A17 LOAD Load factor
A54 STATUS Status
*2
A56 REV NO REV No.
A58 MENU REV MENU REV
A60 SELF CHK Self-check result
B DISPLAY2 Display2
*1
B01 INPUT1 Input value 1
B02 INPUT2 Input value 2
B05 OUTPUT1 Output value 1
B06 OUTPUT2 Output value 2
B11 T1 Temporary memory 1
B12 T2 Temporary memory 2
B13 T3 Temporary memory 3
B14 T4 Temporary memory 4
B15 DI Digital input
B16 DO Digital output
B17 LOAD Load factor
B60 SELF CHK Self-check result
D SET (I/O) Setting (I/O)
*1
D01 TAG NO.1 Tag No.-1
D02 TAG NO.2 Tag No.-2
D03 COMMENT1 Comment-1
D04 COMMENT2 Comment-2
D20 INP TYPE Input type
*3
D22 IN RESIST Input resistor
*3
D27 INPUT1 L_RNG Input-1 low range
*3
D28 INPUT1 H_RNG Input-1 high range
*3
D29 INPUT2 L_RNG Input-2 low range
*3
D30 INPUT2 H_RNG Input-2 high range
*3
D38 OUT1 L_RNG Output-1 low range
*3
D39 OUT1 H_RNG Output-1 high range
*3
D40 OUT2 L_RNG Output-2 low range
*3
D41 OUT2 H_RNG Output-2 high range
*3
D46 PRGM SELECT Program selection
*3
D47 CYCLE TIME Computation cycle
*3
D60 SELF CHK Self-check result
G PROGRAM Program
G01 PROGRAM Program
*3
G02 PROGRAM Program
*3
↓ ↓ ↓
*3
G59 PROGRAM Program
*3
G60 SELF CHK Self-check result
H CONST Fixed constant
H01 CONST Fixed constant
H02 CONST Fixed constant
*3
↓ ↓ ↓
*3
H59 CONST Fixed constant
*3
H60 SELF CHK Self-check result
P ADJUST Adjustment
P08 IN1 ZERO ADJ Input-1 zero adjustment
P09 IN1 SPAN ADJ Input-1 span adjustment
P10 IN2 ZERO ADJ Input-2 zero adjustment
P11 IN2 SPAN ADJ Input-2 span adjustment
P26 OUT1ZERO ADJ Output-1 zero adjustment
P27 OUT1SPAN ADJ Output-1 span adjustment
P28 OUT2ZERO ADJ Output-2 zero adjustment
P29 OUT2SPAN ADJ Output-2 span adjustment
P60 SELF CHK Self-check result
Q TEST Test
Q03 OUT1 TEST Forced output-1
Q04 OUT2 TEST Forced output-2
Q60 SELF CHK Self-check result
*1 The displayed status is to let the service staff know the past
records of the product.
*2 There are items not displayed depending on what output-2 is
specied.
*3 The parameters are the items to be set at the factory.