Instruction Manual

9 - 9IM 11G02M01-01E
Table 9. Measurable Components and Their Corresponding Channel Numbers
Measurable
component
- A N Not specified SO
2
- B N Not specified CO
- C N Not specified CO
2
- D N Not specified CH
4
- E N Not specified NO
- F N Not specified CO
2
CO
- G N Not specified CH
4
CO
- H N Not specified CO
2
CH
4
- J N Not specified CO
2
CO CH
4
- K N Not specified NO SO
2
- L N Not specified NO CO
- M N Not specified NO SO
2
CO
- A 1, 2, 3 Not specified SO
2
O
2
- B 1, 2, 3 Not specified CO O
2
- C 1, 2, 3 Not specified CO
2
O
2
- D 1, 2, 3 Not specified CH
4
O
2
- E 1, 2, 3 Not specified NO O
2
- F 1, 2, 3 Not specified CO
2
CO O
2
- G 1, 2, 3 Not specified CH
4
CO O
2
- H 1, 2, 3 Not specified CO
2
CH
4
O
2
- J 1, 2, 3 Not specified CO
2
CO CH
4
O
2
- K 1, 2, 3 Not specified NO SO
2
O
2
- L 1, 2, 3 Not specified NO CO O
2
- M 1, 2, 3 Not specified NO SO
2
CO O
2
- A 1, 2, 3 /K SO
2
O
2
Correct SO
2
Correct SO
2
av.
O
2
av.
- B 1, 2, 3 /K CO O
2
Correct CO
Correct CO av.
O
2
av.
- E 1, 2, 3 /K NO
X
O
2
Correct NO
X
Correct NO
X
av.
O
2
av.
- F 1, 2, 3 /K CO
2
CO O
2
Correct CO
Correct CO av.
O
2
av.
- G 1, 2, 3 /K CH
4
CO O
2
Correct CO
Correct CO av.
O
2
av.
- J 1, 2, 3 /K CO
2
CO CH
4
O
2
Correct CO
Correct CO av.
O
2
av.
- K 1, 2, 3 /K NO
X
SO
2
O
2
Correct NO
X
Correct SO
2
Correct NO
X
av.
Correct SO
2
av.
O
2
av.
- L 1, 2, 3 /K NO
X
CO O
2
Correct NO
X
Correct CO
Correct NO
X
av.
Correct CO av.
O
2
av.
- M 1, 2, 3 /K NO
X
SO
2
CO O
2
Correct NO
X
Correct SO
2
Correct
CO
O
2
av.
O
2
analyzer
O2 correction CH1 CH2 CH3 CH4 CH5 CH6 CH7
CH8
Suffix/Option Code
Output and Corresponding Channel
* How to Read the Table
“SO2” in the CH1 column means that the display and output of CH1 correspond to SO2 component. “Correct XX” means an instantaneous XX
value after O2 correction, “Correct XX av.” an average XX value after O2 correction, and “O2 av.” an average O2 value.
STANDARD ACCESSORIES
Qty
2
2
1
Item
Part No.
Description
Power cable K9218SA
K9218RB
K9218RC
Fuse
Slide rail
Replacement fuse (250 V AC, 1 A, delay type) x1
Standard inlet type (2.5 m)
Slide rail x1
T11.EPS
Note:
Quantity in this table is the number of accessories supplied as standard.
For instance, two K9218RC parts, i.e., two slide rails, are supplied as standard.
When ordering separately, the required number of parts should be considered.