Owner manual
Table Of Contents
- Introduction
- CONTENTS
- 1. Overview
- 2. Specifications
- 2.1 General Specifications
- 2.2 General use Separate type Detector and Related Equipment
- 2.3 Separate type Detector for High Temperature and Related Equipment
- 2.4 ZR402G Separate type Converter
- 2.5 ZA8F Flow Setting Unit and ZR40H Automatic Calibration Unit
- 2.6 ZO21S Standard Gas Unit
- 2.7 Other Equipments
- 2.7.1 Dust Filter for the Detector (K9471UA)
- 2.7.2 Dust Guard Protector (K9471UC)
- 2.7.3 Ejector Assembly for High Temperature (E7046EC, E7046EN)
- 2.7.4 Stop Valve (L9852CB, G7016XH)
- 2.7.5 Check Valve (K9292DN, K9292DS)
- 2.7.6 Air Set
- 2.7.7 Zero Gas Cylinder (G7001ZC)
- 2.7.8 Cylinder Pressure Reducing Valve (G7013XF, G7014XF)
- 2.7.9 Case Assembly for Calibration Gas Cylinder (E7044KF)
- 2.7.10 ZR22A Heater Assembly
- 3. Installation
- 3.1 Installation of General-purpose Detector
- 3.2 Installation of High Temperature Detector (ZR22G-015)
- 3.3 Installation of the ZR402G Converter
- 3.4 Installation of ZA8F Flow Setting Unit
- 3.5 Installation of ZR40H Automatic Calibration Unit
- 3.6 Installation of the Case Assembly(E7044KF)
- 3.7 Insulation Resistance Test
- 4. Piping
- 5. Wiring
- 6. Components
- 7. Startup
- 7.1 Checking Piping and Wiring Connections
- 7.2 Checking Valve Setup
- 7.3 Supplying Power to the Converter
- 7.4 Touchpanel Switch Operations
- 7.5 Confirmation of Converter Type Setting
- 7.6 Confirmation of Detector Type Setting
- 7.7 Selection of Sample Gas
- 7.8 Output Range Setting
- 7.9 Setting Display Item
- 7.10 Checking Current Loop
- 7.11 Checking Contact I/O
- 7.12 Calibration
- 8. Detailed Data Setting
- 9. Calibration
- 10. Other Functions
- 11. Inspection and Maintenance
- 12. Troubleshooting
- Customer Maintenance Parts List CMPL 11M12A01-02E
- Customer Maintenance Parts List CMPL 11M12C01-01E
- Customer Maintenance Parts List CMPL 11M12A01-11E
- Customer Maintenance Parts List CMPL 11M03B01-10E
- Customer Maintenance Parts List CMPL 11M03B01-05E
- Customer Maintenance Parts List CMPL 11M03D01-01E
- Revision Information

<6. Components>
6-3
IM 11M12A01-02E 8th Edition : Jan.13,2012-00
6.2 ZR402G Converter
Enter
Maintenance
Calibration setup
Blow back setup
mA-output loop check
Contact check
Display setup
F7.6E.ai
Complete Operation Display
■ Interactive operations along with operation display.
■ A variety of display modes - enabling you to select
the operation mode freely.
■ Back-lit LCD allows viewing even in the darkness.
■ Error codes and details of errors can be checked in
the field without the need to refer to appropriate
instruction manual.
This display enables you to operate the analyzer
while checking data on the display.
●
Example of basic display
●
Example of trend display
— displays data changes
Error code Reason for error
E--1 Cell failure
E--2 Abnormal heater temperature
E--3 Defective A/D converter
E--4 Faulty EEPROM
ALARM1 Abnormal oxygen concentration
ALARM2 Abnormal moisture
ALARM3 Abnormal mixing ratio
ALARM6 Abnormal zero calibration ratio
ALARM7 Abnormal span calibration ratio
ALARM8 Stabilization time over
Typical Converter Displays
●
Example of setting data display
— displays data changes
During calibration, you can check the stabilized,
display data while viewing oxygen trend data,thus
providing highly reliable calibration.
● One-touch interactive display operation
● User-friendly design providing easy operation
without having to use the instruction manual
Self-testing suggests countermeasures
for problems
If a problem occurs, the liquid-crystal display will
provide an error code and description of the
problem. This enables prompt and appropriate
corrective action to be taken.
F6-3E.ai
Figure 6.3 Converter