Owner manual

Table Of Contents
<4. Pipomg>
4-12
IM 11M12A01-02E 8th Edition : Jan.13,2012-00
4.4.1 Piping Parts for a System using Detector with
Pressure Compensation
Check that the parts listed in Table 4.3 are ready.
Table 4.3 Piping Parts
Detector Piping location Parts Name Note
Detector with
pressure
compensation
Calibration gas inlet Stop valve or check valve
Recommended by YOKOGAWA (L9852CB or
G7016XH) Provided by YOKOGAWA (K9292DN
or K9292DS)
Nipple * Rc1/4 or 1/4 NPT General parts
Zero gas cylinder User´s scope
Pressure reducing valve Recommended by YOKOGAWA
(G7013XF or G7014XF)
Joint for tube connection Rc1/4 or 1/4 NPT General parts
Reference gas inlet Air set Recommended by YOKOGAWA
(G7003XF / K9473XK or G7004XF / K9473XG)
Joint for tube connection Rc1/4 or 1/4 NPT General parts
Note: Parts with marking * are used when required.
General parts can be found on the local market.
4.4.2 Piping for the Calibration Gas
Calibration gas piping is basically identical to that of System 2. See Section 4.2.2.
4.4.3 Piping for the Reference Gas
Reference gas piping is basically identical to that of for System 2. See Section 4.2.3.