Instruction Manual
  <1. Overview>
1-19
IM 11B08A01-01E
1.7 Features
 Simple operation by touching the screen
The GC-HMI (Human Machine Interface: a 12-inch color LCD touch panel) dramatically improves 
operation and simplifi es maintenance.
 GC modules enable parallel chromatography
Parallel chromatography is made practical with the introduction of the GC Module concept. 
Complex applications are divided into smaller simultaneous measurements, reducing the 
analysis time and allowing confi gurations to be tailored to customers’ needs.
  Gas Chromatograph Module (GCM)
  As a single GCM is equivalent to a single virtual GC, virtual GCs set up on the GC8000 can 
measure multiple streams simultaneously.
 System (SYS)
  SYS is the smallest segment for analysis, and SYSs can be set up in a single GCM. 
Therefore, individual SYS confi gurations allow the GC8000 to measure only the most 
important element with a shorter analysis time among the elements. Each SYS assigned to 
a specifi c GCM analyzes simultaneously, whereas each SYS assigned to a different GCM 
does not.
 Flexible and secure GC network design
  The communications network of the GC8000 is based on the Ethernet structure to transmit 
data to GC workstations and the DCS system. The GC8000 can be set up for either a single 
Ethernet network or a redundant network.
  Modbus TCP/IP protocol support eliminates the need for communication gateways to 
DCS systems in many situations. This not only simplifi es the network architecture, but also 
removes a potential point of failure in delivering analytical data to the DCS system. For 
communication systems that still require Serial Modbus gateways, the ASGW is available.
  For customer sites with an existing Ethernet network for the GC1000 Mark II, the GC8000 is 
fully compatible without having to modify the network.
 State-of-the-art maintenance software
  Re-analysis function of ASET
  Conventional process chromatographs measure concentrations in accordance with 
the preset confi guration for chromatogram analysis. The appropriate confi guration is 
determined by trial-and-error based on the results of many analyses.
  With this function, the GC8000 can measure concentrations in accordance with the most 
appropriate confi guration for chromatograms saved in a fi le after measurements. The result 
can be sent to the analyzer and reused for other measurements. This feature dramatically 
reduces the maintenance time and improves troubleshooting such as mixtures of process 
samples with uncertain components.
  Custom software capability
  With the programming in YM-BASIC (Yokogawa’s original programming language based on 
BASIC), calculation formulas for analysis results and various measurement statuses such 
as stream switching can be changed. This function also allows special calculations using 
analog inputs from other analyzers and contact inputs.
  Gate tracking function
  The automatic peak tracking function of GC1000 Mark II was improved. The setting of 
tracking (correction) conditions of the gate time setting to detect peaks has become fl exible, 
from simultaneously setting all GCs to setting each SYS or each detector. This enables 
precise measurement even in multicomponent analysis such as PIONA.