Instruction Manual
    <7. Troubleshooting>
7-7
IM 11B08A01-01E
 Level 2
 D/I Alarm
No. MESSAGE Alarm Contents Threshold Item Setting Value
201 DI#1 ALARM DI#1 Alarm
202 DI#2 ALARM DI#2 Alarm
203 DI#3 ALARM DI#3 Alarm
204 DI#4 ALARM DI#4 Alarm
205 DI#5 ALARM DI#5 Alarm
206 DI#6 ALARM DI#6 Alarm
207 DI#7 ALARM DI#7 Alarm
208 DI#8 ALARM DI#8 Alarm
209 DI#9 ALARM DI#9 Alarm
210 DI#10 ALARM DI#10 Alarm
211 DI#11 ALARM DI#11 Alarm
212 DI#12 ALARM DI#12 Alarm
213 DI#13 ALARM DI#13 Alarm
214 DI#14 ALARM DI#14 Alarm
215 DI#15 ALARM DI#15 Alarm
216 DI#16 ALARM DI#16 Alarm
217 DI#17 ALARM DI#17 Alarm
218 DI#18 ALARM DI#18 Alarm
219 DI#19 ALARM DI#19 Alarm
220 DI#20 ALARM DI#20 Alarm
221 DI#21 ALARM DI#21 Alarm
222 DI#22 ALARM DI#22 Alarm
223 DI#23 ALARM DI#23 Alarm
224 DI#24 ALARM DI#24 Alarm
225 DI#25 ALARM DI#25 Alarm
226 DI#26 ALARM DI#26 Alarm
227 DI#27 ALARM DI#27 Alarm
228 DI#28 ALARM DI#28 Alarm
229 DI#29 ALARM DI#29 Alarm
230 DI#30 ALARM DI#30 Alarm
231 DI#31 ALARM DI#31 Alarm
232 DI#32 ALARM DI#32 Alarm
 Fixed Alarm
No. MESSAGE Alarm Contents Threshold Item Threshold Threshold 
Setting
251 OVERRIDE Override N/A
252 DUAL ETHER ERR Wrong def. of dual 
Ethernet
IP address Invalid IP address 
setting
Ethernet setting 
screen
253 FILE_READ_ERR File reading error File Error to read N/A
254 FILE_WRITE_ERR File writing error File Error to write N/A
261 HMI SYS ERR HMI system error DO contact for HMI 
Fail
N/A
262 HMI COMM ERR HMI communication 
error
DO contact for HMI 
communication error
N/A
271 OVEN1 COOL ERR Oven 1 cooling error Temperature control 
for programmed 
temperature oven
Temperature control 
does not start when 
analysis starts. 
N/A
272 OVEN2 COOL ERR Oven 2 cooling error
273 OVEN3 COOL ERR Oven 3 cooling error
281 C-OVER Calibration error Calibration range Exceeds the set 
value.
Peak setting 
screen
282 C-REPT Calibration 
repeatability failure
Repeatable 
calibration range
Exceeds the set 
value.
Peak setting 
screen
283 C-COEF Failure of calibration 
coeffi cient
Invalid calibration 
coeffi cient
Exceeds the set 
value.
Peak setting 
screen
291 CONC OUT Concentration 
abnormal
Concentration Exceeds the set 
value.
Alarm setting 
screen
292 RT OUT Retention time 
abnormal
Retention time Exceeds the set 
value.
Alarm setting 
screen
293 DEV OUT Variation coeffi cient 
abnormal
Variation coeffi cient Exceeds the set 
value.
Alarm setting 
screen
294 TAIL OUT Tailing coeffi cient 
abnormal
Tailing coeffi cient Exceeds the set 
value.
Alarm setting 
screen
2nd Edition : May 11, 2012-00