Operation Manual
<8. Operation of DYFMVTool>
8-4
IM 01C25R51-01E
(1) In case of Gas temperature pressure compensation
Step 1
Select the Category from the followings;
• Natural Gas
• Gas (DIPPR)
• Gas (custom data table)
Step 2-1
When“NaturalGas”isselectedfrom“Category”,select“Name/Method”fromthefollowings;
•AGA8DetailCharacterizationMethod
•AGA8GrossCharacterizationMethod1
•AGA8GrossCharacterizationMethod2
• ISO12213 molar-composition analysis
• ISO12213 physical properties
Step 2-2
When“Gas(DIPPR)”isselectedfrom“Category”,select“Name/Method”DYFMVToolsupports
the materials shown in Table 8.2.
Step 2-3
When“Gas(customdatatable)”isselectedfrom“Category”,setthecustomFluidName/Method
in the blank box.
(
2) In case of Liquid temperature compensation
Step 1
Selectthe“Category”fromthefollowings;
• Liquid (DIPPR)
• Liquid (custom data table)
Step 2-1
When“Liquid(DIPPR)”isselectedfrom“Category”,select“Name/Method”.DYFMVTool
supports the materials shown in Table 8.2.
Step 2-2
When“Liquid(customdatatable)”isselectedfrom“Category”,setthecustomFluidName/
Method in the blank box.