User Manual

<10. General Specications>
10-2
IM 01C25T02-01E
10.2 Optional Specications
For items other than those described below, refer to each Users Manual.
Item Description Code
Data conguration at factory Software damping CC
Software Download Function Based on F
OUNDATION eldbus Specication (FF-883)
Download class: Class1
EE
Advanced diagnostics *
3
Multi-sensing process monitoring
Impulse line blockage detection *
1
Heat trace monitoring *
2
DG1
*1: The change of pressure uctuation is monitored and then detects the impulse line blockage. See TI 01C25A31-01E for detailed
technical information required for using this function.
*2: Not applicable for ange mounted differential pressure transmitters and diaphragm sealed differential pressure transmitters
*3: Applicable for EJX series. This option code must be specied with option code EE.
10.3 Optional Specications (For Explosion Protected type)
Item Description Code
Factory Mutual (FM)
FM Explosionproof *
1
FF1
FM Intrinsically safe and Nonincendive *
1
FS15
ATEX
ATEX Flameproof *
1
KF22
ATEX Intrinsically safe Ex ia *
1
KS26
ATEX Intrinsically safe Ex ic *
1
KN26
Canadian Standards
Association (CSA)
CSA Explosionproof *
1
CF1
CSA Intrinsically safe *
1
CS15
IECEx Scheme
IECEx Flameproof *
1
SF2
IECEx Intrinsically safe and type n *
1
SS25
Contact Yokogawa representative for the codes indicated as ‘-’.
*1: Applicable for Electrical connection code 2, 4, 7, 9, C and D .
< Factory Setting >
Tag Number (Tag plate) As specied in order
Software Tag (PD_TAG) ‘PT2001’ unless otherwise both Tag Number and Software Tag
specied in order
Node Address ‘0xF5’ unless otherwise specied in order
Operation Functional Class ‘BASIC’ or as specied
Primary value *
1
Output Mode (L_TYPE) ‘Direct’ unless otherwise specied in order
Calibration Range (XD_SCALE)
Lower/Higher Range Value
As specied in order
Calibration Range Unit Selected from mmH
2O, mmH2O(68°F), mmHg, Pa, hPa, kPa,
MPa, mbar, bar, gf/cm
2
, kgf/cm
2
, inH2O, inH2O(68°F), inHg,
ftH
2O, ftH2O(68°F) or psi. (Only one unit can be specied)
Output Scale (OUT_SCALE)
Lower/Higher Range Value
‘0 to 100%’ unless otherwise specied.
Software Damping *
2
‘2 seconds’ or as specied in order
Static pressur display range ‘0 to 25 MPa’ for M and H capsule and0 to 16 MPa for L
capsule, absolute value. Measuring high pressure side.
*1: Primary means differential pressure in case of differential pressure transmitters and pressure in case of pressure transmitters.
*2: To specify this item, /CC option is required.