<10. General Specications>
10-1
IM 01C25T02-01E
10. General Specications
10.1 Standard Specications
For items other than those described below,
refer to each Users Manual.
Applicable Model:
All DPharp EJX/EJA series.
Output:
Digital communication signal based on
F
OUNDATION Fieldbus protocol.
Supply Voltage:
9 to 32 V DC for general use, ameproof type
and Type n
9 to 24 V DC for intrinsically safe type Entity
model
9 to 17.5 V DC for intrinsically safe type FISCO
model
Communication Requirements:
Supply Voltage: 9 to 32 V DC
Current Draw (Stedy state): 15 mA (max)
Current Draw (Software Download state):
24 mA (max)
Update Period:
Differential Pressure: 100 ms
Static Pressure: 100 ms
Capsule Temperature: 1 s
Amplier Temperature: 1 s
Integral Indicator (LCD display):
5-digit Numerical Display, 6-digit Unit Display
and Bar graph. The indicator is congurable
to display one or up to four of the I/O signals
periodically.
Functional Specications:
Functional specications for Fieldbus
communication conform to the standard
specications (H1) of F
OUNDATION Fieldbus.
Function Block:
Block
name
Number
Execution
time
Note
AI 3 30 mS For differential pressure,
static pressure and
temperature
SC 1 30 mS An Output of Signal
Characterizer block is
a non-linear function of
the respective input. The
function is determined by
a table
IT 1 30 mS Integrator block integrates
a variable as a function of
the time or accumulates
the counts
IS 1 30 mS Input Selector block
provides selection of up to
eight inputs and generate
an output based on the
congured action
AR 1 30 mS Arithmetic block permits
simple use of popular
measurement math
functions
PID 1 45 mS Works as a eld PID
controller in conjunction
with other function blocks.
LM Function:
LM function is supported.
LM function is disabled when shipped.