User Manual

<9. Parameter Lists>
9-7
IM 01C25T02-01E
Relative
Index
Index Parameter Name Factory Default
Write
Mode
Explanation
54 2054 CAP_GASKET_MTL Depend on
Specify
O/S Material of capsule gasket
55 2055 FLANGE_MTL Depend on
Specify
O/S Material of ange
56 2056 D_VENT_PLUG Depend on
Specify
O/S Material of drain or vent plug
57 2057 FLANGE_TYPE Depend on
Specify
O/S Flange type
58 2058 REM_SEAL_
ISOL_MTL
Depend on
Specify
O/S Material of isolating diaphragms for remote seal
59 2059 FLANGE_SIZE Depend on
Specify
O/S Flange size
60 2060 REM_SEAL_ NUM Depend on
Specify
O/S Number of remote seal
61 2061 REM_SEAL_
FILL_FLUID
Depend on
Specify
O/S Types of ll uid in remote seals.
62 2062 REM_SEAL_ TYPE Depend on
Specify
O/S Types of remote seals
63 2063 ALARM_SUM Alarm Disable The current alert status, unacknowledged states, unreported
states, and disabled states of the alarms associated with the
function block.
64 2064 AUTO_RECOVERY 1 (ON) O/S Permission of auto recovery from sensor errors
65 2065 MS_CODE Null Model sufx and codes
66 2066 DIAG_MODE Stop (0) Used for ILBD. Refer to A8.2.12.
67 2067 DIAG_PERIOD 180 (s) Used for ILBD. Refer to A8.2.12.
68 2068 DIAG_PRI 1 Used for ILBD. Refer to A8.2.12.
69 2069 DIAG_ERR 0x0000 Used for ILBD. Refer to A8.2.12.
70 2070 DIAG_H_ALM Used for ILBD. Refer to A8.2.12.
71 2071 DIAG_L_ALM Used for ILBD. Refer to A8.2.12.
72 2072 DIAG_OPTION 0x08FC Used for ILBD. Refer to A8.2.12.
73
2073 REF_LIM_FDPMIN 7E-10 Used for ILBD. Refer to A8.2.12.
74 2074 REF_LIM_FSPMIN 1E-10 Used for ILBD. Refer to A8.2.12.
75 2075 REF_LIM_BLKFMAX 0.5 Used for ILBD. Refer to A8.2.12.
76 2076 COMP_FLAG 0 Used for ILBD. Refer to A8.2.12.
77 2077 DIAG_LIM Refer to Table
A8.2
Used for ILBD. Refer to A8.2.12.
78 2078 DIAG_COUNT 3, 3, 3, 3, 3 Used for ILBD. Refer to A8.2.12.
79 2079 REFERENCE_TIME 0x00000000 Used for ILBD. Refer to A8.2.12.
80 2080 REFERENCE_FDP 0x00, 0 Used for ILBD. Refer to A8.2.12.
81 2081 REFERENCE_FSPL 0x00, 0 Used for ILBD. Refer to A8.2.12.
82 2082 REFERENCE_FSPH 0x00, 0 Used for ILBD. Refer to A8.2.12.
83 2083 REFERENCE_BLKF 0x00, 0 Used for ILBD. Refer to A8.2.12.
84 2084 REFERENCE_DPAVG 0x00, 0 Used for ILBD. Refer to A8.2.12.
85 2085 VALUE_TIME Used for ILBD. Refer to A8.2.12.
86 2086 VALUE_FDP Used for ILBD. Refer to A8.2.12.
87 2087 VALUE_FSPL Used for ILBD. Refer to A8.2.12.
88 2088 VALUE_FSPH Used for ILBD. Refer to A8.2.12.
89 2089 VALUE_BLKF Used for ILBD. Refer to A8.2.12.
90 2090 VALUE_DPAVG Used for ILBD. Refer to A8.2.12.
91 2091 RATIO_FDP Used for ILBD. Refer to A8.2.12.
92 2092 RATIO_FSPL Used for ILBD. Refer to A8.2.12.
93 2093 RATIO_FSPH Used for ILBD. Refer to A8.2.12.
94 2094 CRATIO_FDP Used for ILBD. Refer to A8.2.12.
95 2095 NRATIO_FDP Used for ILBD. Refer to A8.2.12.
96 2096 DIAG_APPLICABLE Used for ILBD. Refer to A8.2.12.
97 2097
FLG_TEMP_VAL 0 Used for Heat trace monitoring. Refer to A8.3.6.
98 2098 FLG_TEMP_RANGE -50.0 to 130.0°C Used for Heat trace monitoring. Refer to A8.3.6.
99 2099 FLG_TEMP_COEF 0 Used for Heat trace monitoring. Refer to A8.3.6.
100 2100 FLG_TEMP_PRI 1 Used for Heat trace monitoring. Refer to A8.3.6.
101 2101 FLG_TEMP_H_LIM 130 Used for Heat trace monitoring. Refer to A8.3.6.