<9. Parameter Lists>
9-6
IM 01C25T02-01E
Relative
Index
Index Parameter Name Factory Default
Write
Mode
Explanation
18 2018 CAL_MIN_SPAN Minimum span of
capsule
— The minimum calibration span value allowed.
19 2019 CAL_UNIT kPa — The engineering unit for the calibrated values.
20 2020 SENSOR_TYPE Silicon resonant — The type of sensor.
21 2021 SENSOR_ RANGE Range of capsule — The High and Low range limit values, engineering units code
and the number of digits to the right of the decimal point for the
sensor.
22 2022 SENSOR_SN Serial No. — Serial number.
23 2023 SENSOR_CAL_
METHOD
103: factory
trim standard
calibration
O/S The method of the last sensor calibration.
100=volumetric
101=static weight
102=dynamic weight
103=factory trim standard calibration
104=user trim standard calibration
105=factory trim special calibration
106=user trim special calibration
255=Other
24 2024 SENSOR_CAL_LOC — O/S Set/indicate the location of the last sensor calibration.
25 2025 SENSOR_CAL_DATE — O/S Set/indicate the date of the last sensor calibration.
26 2026 SENSOR_CAL_WHO — O/S Set/indicate the name of the person responsible for the last
sensor calibration.
27 2027 SENSOR_
ISOLATOR_MTL
Unkown — Denes the construction material of the isolating diaphragms.
28 2028 SENSOR_FILL_
FLUID
Unkown — Denes the type of uid used in the sensor.
29 2029 SECONDARY_VALUE — Static pressure (high pressure side) value and status
30 2030 SECONDARY_
VALUE_UNIT
1133 (KPa) — The engineering unit of static pressure (high pressure side).
This unit is linked to XD_SCALE.unit of AI blocks
31 2031 CAL_DEVIATION_HI 0 O/S Deviation value for span adjustment.
32 2032 CAL_DEVIATION_LO 0 O/S Deviation value for zero adjustment.
33 2033 EXTERNAL_ZERO_
TRIM
0 O/S Permission of external zero-adjustment
34 2034 PRIMARY_VALUE_
FTIME
2 O/S Damping time constant for primary value
35 2035 TERTIARY_VALUE —
Value and status of static pressure at low side
36 2036 SP_VALUE_TYPE 109 (absolute
pressure)
O/S Select the type of measurement for static pressure, absolute
or gauge
37 2037 SP_VALUE_RANGE Range of capsule — High and low range limit values, engineering units, and decimal
point place for static pressure.
38 2038 CAL_SP_ POINT_HI 16 O/S The highest calibrated value for static pressure
39 2039 CAL_SP_ POINT_LO 0 O/S The Lowest calibrated value for static pressure
40 2040 CAL_SP_MIN_ SPAN 1.0 — The minimum calibration span allowed for static pressure
41 2041 CAL_SP_UNIT 1133 (KPa) — The calibrated engineering unit for static pressure. This unit is
linked to XD_SCALE.unit of AI blocks
42 2042 CAL_SP_
DEVIATION_HI
0 O/S Deviation value for span adjustment of static pressure
43 2043 CAL_SP_
DEVIATION_LO
0 O/S Deviation value for zero adjustment of static pressure
44 2044 SP_VALUE_FTIME 2 O/S Damping time constant for static pressure
45 2045 ATM_PRESS 101.325 O/S Atmosphere pressure value used to obtain gauge pressure
value from absolute pressure.
46 2046 CLEAR_CAL 0 O/S Reset zero and span adjustment to factory calibrated values for
pressure, static pressure, and or all.
47 2047 CAP_TEMP_VAL — Measured capsule temperature value and status.
48 2048 CAP_TEMP_RANGE -50.0 to 130.0°C — High and low range limit values, engineering units, decimal
point place for capsule temperature.
49 2049 AMP_TEMP_VAL — Measured Amplier temperature value and status.
50 2050 AMP_TEMP_ RANGE -50.0 to 95.0°C — High and low range limit values, engineering units, decimal
point place for Amplier temperature.
51 2051 MODEL Model code — The model code.
52 2052 SPECIAL_ ORDER_
ID
Special order
number
— Identication number of special order.
53 2053 MANUFAC_DATE 0 O/S Date of production