User Manual

<2. Handling Cautions>
2-12
IM 01C25T02-01E
2.1.4 IECEx Certication
a. IECEx Flameproof Type
Caution for IECEx ameproof type.
Note 1. The transmitters with optional code /SF2
are applicable for use in hazardous
locations:
No. IECEx CSA 07.0008
Applicable Standard:
IEC60079-0:2004, IEC60079-1:2003
Flameproof for Zone 1, Ex d IIC T6...T4
Enclosure: IP66 and IP67
Maximum Process Temperature:
120°C (T4), 100°C (T5), 85°C (T6)
Ambient Temperature:
–50* to 7C (T4), –50* to 80°C (T5),
–50* to 7C (T6)
* –15°C when /HE is specied.
Supply Voltage: 32 V dc max.
Output Signal: 15 mA dc
Note 2. Wiring
In hazardous locations, the cable entry
devices shall be of a certied ameproof
type, suitable for the conditions of use and
correctly installed.
Unused apertures shall be closed with
suitable ameproof certied blanking
elements.
Note 3. Operation
WARNING:
AFTER DE-ENERGIZING, DELAY 5
MINUTES BEFORE OPENING.
WARNING:
WHEN AMBIENT TEMPERATURE 65°C,
USE THE HEAT-RESISTING CABLES
90°C.
Take care not to generate mechanical
sparking when accessing to the instrument
and peripheral devices in a hazardous
location.
Note 4. Maintenance and Repair
The instrument modication or parts
replacement by other than authorized
representative of Yokogawa Electric
Corporation is prohibited and will void IECEx
Certication.
b. IECEx Intrinsically Safe Type / type n
Caution for IECEx Intrinsically safe and type n.
Note 1. The transmitters with optional code /SS25
are applicable for use in hazardous
locations
No. IECEx CSA 05.0012
Applicable Standard:
IEC 60079-0:2000, IEC 60079-11:1999,
IEC 60079-15:2001
Ex ia IIC/IIB T4, Ex nL IIC T4
Ambient Temperature: –40* to 60°C
* –15°C when /HE is specied.
Max. Process Temp.: 120°C
Enclosure: IP66 and IP67
Note 2. Entity Parameters
Intrinsically safe ratings are as follows:
[Entity]
Maximum Input Voltage (Vmax/Ui) = 24 V
Maximum Input Current (Imax/Ii) = 250 mA
Maximum Input Power (Pmax/Pi) = 1.2 W
Maximum Internal Capacitance (Ci)
= 1.76 nF
Maximum Internal Inductance (Li) = 0 µH
[FISCO IIC]
Maximum Input Voltage (Vmax/Ui) = 17.5 V
Maximum Input Current (Imax/Ii) = 380 mA
Maximum Input Power (Pmax/Pi) = 5.32 W
Maximum Internal Capacitance (Ci)
= 1.76 nF
Maximum Internal Inductance (Li) = 0 µH
[FISCO IIB]
Maximum Input Voltage (Vmax/Ui) = 17.5 V
Maximum Input Current (Imax/Ii) = 460 mA
Maximum Input Power (Pmax/Pi) = 5.32 W
Maximum Internal Capacitance (Ci)
= 1.76 nF
Maximum Internal Inductance (Li) = 0 µH
Type "n" ratings are as follows:
Maximum Input Voltage (Vmax/Ui) = 32 V
Maximum Internal Capacitance (Ci)
= 1.76 nF
Maximum Internal Inductance (Li) = 0 µH
Installation Requirements
Uo Ui, Io Ii, Po Pi,
Co Ci + Ccable, Lo Li + Lcable
Voc Vmax, Isc Imax,
Ca Ci + Ccable, La Li + Lcable
Uo, Io, Po, Co, Lo, Voc, Isc, Ca and La are
parameters of barrier.