User Manual
    <2.  Handling Cautions>
2-11
IM 01C25T02-01E
(2)  Electrical Connection
A mark indicating the electrical connection type is 
stamped near the electrical connection port. These 
marks are as follows.
F0210.ai
Location of the mark
Screw Size
ISO M20 × 1.5 female
ANSI 1/2 NPT female
Marking
 M
 N or W
(3)  Installation  
WARNING
•  All wiring shall comply with local installation 
requirements and the local electrical code. 
•  There is no need for a conduit seal in 
Division 1 and Division 2 hazardous 
locations because this product is sealed at 
the factory.
(4)  Operation
WARNING
•  OPEN CIRCUIT BEFORE REMOVING 
COVER. INSTALL IN ACCORDANCE WITH 
THIS USER’S MANUAL 
•  Take care not to generate mechanical 
sparking when accessing the instrument and 
peripheral devices in a hazardous location. 
(5)  Maintenance and Repair  
WARNING
The instrument modication or part replacement 
by other than an authorized Representative of 
Yokogawa Electric Corporation is prohibited and 
will void the certication. 
(6)  Name Plate
 Name plate
 Tag plate for flameproof type
 Tag plate for intrinsically safe type
F0211.ai
AFTER DE-ENERGIZING, DELAY 5 MINUTES
BEFORE OPENING. 
WHEN THE AMBIENT TEMP. ≥ 65°C,
USE THE HEAT-RESISTING CABLE AND CABLE GLAND ≥ 90°C
POTENTIAL ELECTROSTATIC CHARGING HAZARD
No. KEMA 07ATEX0109 X
Ex d IIC T6...T4 Gb, Ex tb IIIC T85°C Db
Enlcosure : IP66, IP67
TEMP. CLASS T6 T5 T4
MAX PROCESS TEMP.(Tp.) 85 100 120 °C
Tamb. -50 to 75 80 75 °C 
T85°C(Tamb.:-30(-15) to 75°C, Tp.:85°C)(for Dust)
: Refer to USER'S MANUAL.
Made in Japan
TOKYO 180-8750 JAPAN
MODEL
SUFFIX
SUPPLY
OUTPUT
MWP
mA DC
V DC
STYLE
CAL
RNG
NO.
WARNING
D
WARNING
No. KEMA 04ATEX1116 X 
Ex ia IIC/IIB T4 Ga Ta:-40 to 60°C 
Ex ia IIIC T85°C T100°C T120°C Db Ta:-30(-15) to 60°C 
MAX PROCESS TEMP.(Tp.):120°C
T85°C(Tp.:80°C), T100°C(Tp.:100°C), T120°C(Tp.:120°C)
Enclosure: IP66/IP67
FISCO field device(IIC/IIB)
Entity parameters Ui=24V, Ii=250mA, Pi=1.2W, Ci=3.52nF, Li=0μH
WARNING
POTENTIAL ELECTROSTATIC CHARTGING HAZARD - SEE USER'S MANUAL.
D
 Tag plate for intrinsically safe Ex ic
Ex ic IIC T4 Gc
IP66
Tamb -30(-15) TO 60°C 
MAX. PROCESS TEMP. 120°C
Ui=32V, Ci=3.52nF, Li=0µH
POTENTIAL ELECTROSTATIC CHARGING HAZARD - SEE USER'S MANUAL.
*3
MODEL: Specied model code.
STYLE: Style code.
SUFFIX: Specied sufx code.
SUPPLY: Supply voltage.
OUTPUT: Output signal. 
MWP: Maximum working pressure. 
CAL RNG: Specied calibration range. 
NO.: Serial number and year of production*
1
.
TOKYO 180-8750 JAPAN: 
The manufacturer name and the address*
2
.
*1:  The rst digit in the nal three numbers of the serial 
number appearing after “NO.” on the name plate indicates 
the year of production. The following is an example of a 
serial number for a product that was produced in 2010: 
The year 2010
91K819857 032
*2:  “180-8750” is the Zip code for the following address. 
2-9-32 Nakacho, Musashino-shi, Tokyo Japan 
*3:  The identication number of Notied Body.