User guide
    <4.  Diagnostics>
4-3
IM 01C25R05-01EN
Integral 
Indicator
DTM 
display
Status 
group
Cause Countermeasure
Value and Status (Data Quality and Limit Status)
Differential 
Pressure 
(DP)
Static 
Pressure 
(SP)
External  
Temperature 
(ET)
DP % SP % ET %
AL.10 
PRESS
P outside 
limit
3 Differential 
pressure 
is outside 
measurement
range limit of 
capsule.
Check input 
or replace 
capsule when 
necessary.
Value:
Measured value
Status:
Poor Accuracy and 
Not Limited
(0x40)
Value:
Measured 
value
Status:
Good and 
Not Limited
(0xC0)
Value:
Measured value
Status:
Poor Accuracy and 
Not Limited
(0x40)
Value:
Measured 
value
Status:
Good 
and Not 
Limited
(0xC0)
AL.11 
ST.PRSS
SP outside 
limit
Static pressure 
exceeds limit.
AL.12 
CAP.TMP
CT outside 
limit
Capsule 
temperature is 
outside range 
(–50 to 130°C).
Use heat 
insulation or 
make lagging 
to keep 
temperature 
within range.
AL.13 
AMP.TMP
AT outside 
limit
Amplier 
temperature is 
outside range 
(–50 to 95°C).
Value: Measured value
Status: Good and Not Limited
(0xC0)
Value: Measured value
Status: Good and Not Limited
(0xC0)
AL.14 
EXT.TMP
ET outside 
limit
External 
temperature is 
outside range.
Value:
Measured value
Status:
Good and Not Limited
(0xC0)
Value:
Measured 
value
Status:
Poor 
Accuracy 
and Not 
Limited
(0x40)
Value:
Measured value
Status:
Good and Not Limited
(0xC0)
Value:
Measured 
value
Status:
Poor 
Accuracy 
and Not 
Limited
(0x40)
AL.15 
EXT.TMP
OHM 
outside 
limit
External 
temperature 
sensor 
resistance is out 
specication.
AL.30 
PRS.RNG
P over 
range
4 Differential 
pressure 
exceeds 
specied range.
Check input 
and range 
setting, and 
change them 
as needed.
Value:
Measured value
Status:
Good and Not Limited
(0xC0)
Value: 
Hold value
Status: 
Bad and 
Constant
(0x30)
Value:
Measured value
Status:
Good and Not Limited
(0xC0)
AL.31 
SP. RNG
SP over 
range
Static pressure 
exceeds
specied range.
Value:
Measured 
value
Status:
Good 
and Not 
Limited
(0xC0)
Value: 
Hold value
Status: 
Bad and 
Constant
(0x30)
Value:
Measured 
value
Status:
Good 
and Not 
Limited
(0xC0)
AL.33 
ET. RNG
ET over 
range
External 
temperature 
exceeds 
specied range.
Value:
Measured value
Status:
Good and Not Limited
(0xC0)
Value: 
Hold value
Status: 
Bad and 
Constant
(0x30)