Manual
    <10.  General Specications>
10-13
IM 01C25R01-01E
Item Description Code
Material certicate *
8
Cover ange 
*9
M01
Cover ange, Process connector 
*10
M11
Pressure test Leak test 
certicate *
11
Test Pressure: 16 MPa (2300 psi) 
*12
Nitrogen (N
2
) Gas 
*14
Retention time: one minute
T12
Test Pressure: 25 MPa (3600 psi) 
*13
T13
Test Pressure: 32 MPa (4500 psi) 
*21
Nitrogen (N
2
) Gas or Water 
*20
Retention time: one minute
T09
*1:  Not applicable with color change option.
*2:  Applicable for Wetted parts material code S.
*3:  The unit of MWP (Max. working pressure) on the name plate of a housing is the same unit as specied by option codes D1, D3, and 
D4.
*4:  Applicable for vertical impulse piping type (Installation code 7) and Wetted parts material code S.
*5:  Applicable for output signal codes E and J. The hardware error indicates faulty amplier or capsule.
*6:  Applicable for wetted parts material code S; process connection codes 3, 4, and 5; installation code 9; and mounting bracket code 
N. Process connection faces on the other side of zero adjustment screw.
*7:  Also see ‘Ordering Information’.
*8:  Material traceability certication, per EN 10204 3.1B.
*9:  Applicable for process connections codes 0 and 5.
*10:  Applicable for process connections codes 1, 2, 3, and 4.
*11:  The unit on the certicate is always Pa unit regardless of selection of option code D1, D3 or D4.
*12:  Applicable for EJX910A capsule code L.
*13:  Applicable for EJX910A capsule codes M and H.
*14:  Pure nitrogen gas is used for oil-prohibited use (option codes K1, K2, K5, and K6).
*15:  Applicable for output signal code -F.
*16:  Applicable for measurement span code M and H. If compliance with category III is needed, specify this code.
*17:  316 or 316L SST. The specication is included in amplier code 2. Not applicable for external temperature input code -1, -2, -3 and 
-4.
*18:  This option code must be specied with option code EE.
*19:  The change of pressure uctuation is monitored and then detects the impulse line blockage. See TI 01C25A31-01E for detailed 
technical information required for using this function.
*20:  Pure nitrogen gas or pure water is used for oil-prohibited use (option codes K1, K2, K5, and K6).
*21:  Applicable for EJX930A.