<10. General Specications>
10-12
IM 01C25R01-01E
Item Description Code
Painting Color change Amplier cover only
P
Amplier cover and terminal cover, Munsell 7.5 R4/14 PR
Coating
change
Anti-corrosion coating
*1
X2
316 SST exterior parts 316 SST name plate, tag plate and zero-adjustment screw
*17
HC
Fluoro-rubber O-ring All O-rings of amplifier housing. Lower limit of ambient temperature: –15°C(5°F) HE
Lightning protector HART protocol type:
Transmitter power supply voltage: 10.5 to 32 V DC
Allowable current: Max. 6000 A (1×40 μs), Repeating 1000 A (1×40 μs) 100 times
Applicable Standards: IEC 61000-4-4, IEC 61000-4-5
F
OUNDATION eldbus protocol type:
Allowable current: Max. 6000 A (1×40 μs), Repeating 1000 A (1×40 μs) 100 times
Applicable Standards: IEC 61000-4-4, IEC 61000-4-5
Modbus protocol type:
Applicable Standards: IEC 61000-4-5
A
Oil-prohibited use
*2
Degrease cleansing treatment K1
Degrease cleansing treatment with uorinated oillled capsule.
Operating temperature –20 to 80°C( –4 to 176°F)
K2
Oil-prohibited use with
dehydrating treatment
*2
Degrease cleansing and dehydrating treatment K5
Degrease cleansing and dehydrating treatment with uorinated oillled capsule.
Operating temperature –20 to 80°C( –4 to 176°F)
K6
Capsule ll uid Fluorinated oil lled in capsule
Operating temperature –20 to 80°C( –4 to 176°F)
K3
Calibration units *
3
P calibration (psi unit)
(See Table for Span and Range
Limits.)
D1
bar calibration (bar unit) D3
M calibration (kgf/cm
2
unit) D4
Gold-plated diaphragm Surface of isolating diaphragm is gold plated, effective for hydrogen permeation. A1
Long vent *
4
Total length: 119 mm (standard: 34 mm); Total length when combining with option code
K1, K2, K5, and K6: 130 mm. Material: 316 SST
U1
Output limits and failure
operation *
5
(for HART protocol type)
Failure alarm down-scale: Output status at CPU failure and hardware error is –2.5%,
3.6 mA DC or less.
C1
NAMUR NE43 Compliant
Output signal limits:
3.8 mA to 20.5 mA
Failure alarm down-scale: Output status at CPU failure
and hardware error is –2.5%, 3.6 mA DC or less.
C2
Failure alarm up-scale: Output status at CPU failure and
hardware error is 110%, 21.6 mA or more.
C3
Body option
*6
F1004.ai
HL
Terminal
Side
Right side high pressure, without drain and vent plugs N1
N1 and Process connection, based on IEC61518 with female thread on both sides of
cover ange, with blind kidney anges on back.
N2
N2, and Material certificate for cover flange, diaphragm, capsule body, and blind
kidney ange
N3
Stainless steel tag plate 304 SST tag plate wired onto transmitter (316 SST when/HC is specied) N4
Data conguration at
factory *
7
Data conguration for HART communication type Software damping,
Descriptor, Message
CA
Data conguration for Fieldbus communication type Software damping CC
Data conguration for Modbus communication type Software damping,
Descriptor, Message
CE
PID function
*15
(For FOUNDATION Fieldbus protocol type)
PID control function
LC1
Advanced diagnostics
(For HART or
F
OUNDATION Fieldbus
protocol type)
Multi-sensing process monitoring
• Impulse line blockage detection
*19
• Heat trace monitoring
HART communication type DG6
Fieldbus communication type
*18
DG1
Software downloading
function
*15
(For FOUNDATION Fieldbus protocol type)
Based on F
OUNDATION Fieldbus Specication (FF-883) Download class: Class1
EE
European Pressure
Equipement Directive
*16
PED 97/23/EC Category III, Module H, type of equipment: Pressure accessory-vessel,
Tupe of uid: Liquid and Gas, Group of uid: 1 and 2
Lower limit of Process and Ambient temperature for EJX910A: –29°C
PE3