Manual
    <3.  Handling Cautions>
3-8
IM 01C25R01-01E
WARNING
To satisfy IP66 or IP67,  apply waterproof glands 
to the electrical connection port.
c.  ATEX Intrinsically Safe Type/ATEX 
Flameproof Type/ATEX Type n 
EJX multivariable transmitters with optional code  
/KU22 can be selected the type of protection ATEX 
Intrinsically Safe, Flameproof or ATEX Type n for 
use in hazardous locations.
Note 1. For the installation of this transmitter, 
once a particular type of protection is 
selected, any other type of protection 
cannot be used. The installation must be in 
accordance with the description about the 
type of protection in this user’s manual.
Note 2. In order to avoid confusion, unnecessary 
marking is crossed out on the label other 
than the selected type of protection when 
the transmitter is installed. 
  CENELEC ATEX Type of Protection “n”
•  Applicable Standard: EN 60079-15:2005,  
EN 60079-0:2009
•  Type of Protection and Marking Code:  
Ex nL IIC T4 Gc
•  Group: II
•  Category: 3G
•  Temperature Class: T4
•  Enclosure: IP66 / IP67
•  Process Temperature: 120°C max.
•  Ambient Temperature: –30* to 60°C
    * –15°C when /HE is specied.
Note 1. Electrical Data
[Supply and Pulse circuit]
Ui = 30 V
Ci = 10 nF
Li = 0 mH
[Sensor circuit]
Uo =7.4 V
Io = 25 mA
Po = 46.3 mW
Co = 11 nF
Lo = 3.9 mH
Note 2. Installation
•  All wiring shall comply with local installation 
requirements. (refer to the installation 
diagram)
Note 3. Maintenance and Repair
•  The instrument modication or parts 
replacement by other than authorized 
representative of Yokogawa Electric 
Corporation is prohibited and will void Type 
of Protection “n”.
Transmitter
Supply
Associated
Apparatus
Nonhazardous Location
[Installation Diagram]
Hazardous Location
+ 
– 
+ 
– 
F0306.ai
Associated
Apparatus
Associated
Apparatus
Sensor out
RTD sensor 
Note 1
 Without pulse output 
 With pulse output 
Transmitter
Supply
Nonhazardous Location
Hazardous Location
Sensor out
RTD sensor 
Note 1
Pulse
Note 1:
  •  RTD sensor is prepared by the user.
  •  The sensor signal line must withstand a test voltage of 
500Vac.
Note 4. Special Conditions for Safe Use
WARNING
•  Electrostatic charge may cause an exlosion 
hazard.  Avoid any actions that cause the 
gerenation of eletrostatic charge, such as 
rubbing with a dry cloth on coating face of 
the  product