Manual
    <3.  Handling Cautions>
3-6
IM 01C25R01-01E
3.9.3  ATEX Certication
ATEX Certication
(1) Technical Data
a.  ATEX Flameproof Type
Caution for ATEX ameproof type.
Note 1. Model EJX Series pressure transmitters 
with optional code /KF22 for potentially 
explosive atmospheres:
•  No. KEMA 07ATEX0109 X
•  Applicable Standard: EN 60079-0:2009,  
EN 60079-1:2007,  EN 60079-31:2009
•  Type of Protection and Marking Code: 
  Ex d IIC T6...T4 Gb,  Ex tb  IIIC  T85°C Db
•  Group: II
•  Category: 2G, 2D
•  Enclosure: IP66 / IP67
•  Temperature Class for gas-poof:  
T6, T5, and T4
•  Ambient Temperature for gas-proof:  
–50 to 75°C (T6), –50 to 80°C (T5), and 
–50 to 75°C (T4)
•  Maximum Process Temperature (Tp.) for 
gas-proof:
  85°C (T6), 100°C (T5), and 120°C (T4)
•  Maximum Surface Temperature for dust-
proof: 
T85°C (Tamb.: –30* to 75°C, Tp.: 85°C) 
*  –15°C when /HE is specied.
Note 2. Electrical Data
•  Power Supply:  
42 V dc max. (HART Communication Type) 
9 to 30 V dc, 250 mW (Modbus 
Communication Type)
•  Output signal:  
4 to 20 mA (HART Communication Type) 
Modbus (Modbus Communication Type) 
For FOUNDATION Fieldbus communication 
type, refer to IM 01C25R03-01E.
Note 3. Installation
•  All wiring shall comply with local installation 
requirement.
•  The cable entry devices shall be of a certied 
ameproof type, suitable for the conditions of 
use.
Note 4. Operation
•  Keep the “WARNING” label attached to the 
transmitter.
  WARNING: AFTER DE-ENERGIZING, 
DELAY 5 MINUTES BEFORE OPENING. 
WHEN THE AMBIENT TEMP.≥65°C, USE 
HEAT-RESISTING CABLE AND CABLE 
GLAND ≥90°C.
•  Take care not to generate mechanical 
sparking when accessing to the instrument 
and peripheral devices in a hazardous 
location.
Note 5. Special Conditions for Safe Use
WARNING
•  Electrostatic charge may cause an exlosion 
hazard.  Avoid any actions that cause the 
gerenation of eletrostatic charge, such as 
rubbing with a dry cloth on coating face of the  
product.
•  In the case where the enclosure of the 
Pressure Transmitter is made of aluminium, 
if it is mounted in an area where the use of 
category 2D apparatus is required, it shall 
be installed in such a way that the risk from 
electrostatic discharges and propagating 
brush discharges caused by rapid ow of 
dust is avoided.
•  The instrument modication or parts 
replacement by other than an authorized 
Representative of Yokogawa Electric 
Corporation is prohibited and will void the 
certication.
•  To satisfy IP66 or IP67, apply waterproof 
glands to the electrical connection port.
b.  ATEX Intrinsically Safe Type
Caution for ATEX Intrinsically safe type.
Note 1. Model EJX Series Multivariable transmitter 
with optional code /KS2 for potentially 
explosive atmospheres:
•  No. KEMA 06ATEX0037 X
•  Applicable Standard: EN 50014:1997,  
EN 50020:2002,  EN 50284:1999,  
EN 50281-1-1:1998
•  Type of Protection and Marking code:  
EEx ia IIC T4
•  Group: II
•  Category: 1G, 1D