Manual
<9. Parameter Lists>
9-14
IM 01C25R03-01E
9.6 Parameter Names Cross
Reference
Parameter’s name may appear differently
according to the tool you use. If you cannot nd the
designated parameters in the parameters list in the
former sections, please use the following cross lists.
Sensor Transducer Block
Relative
Index
Parameter Name Label
0 BLOCK_HEADER Characteristics
1 ST_REV Static Revision
2 TAG_DESC Tag Description
3 STRATEGY Strategy
4 ALERT_KEY Alert Key
5 MODE_BLK Block Mode
6 BLOCK_ERR Block Error
7 UPDATE_EVT Update Event
8 BLOCK_ALM Block Alarm
9 TRANSDUCER_
DIRECTORY
Transducer Directory
Entry
10 TRANSDUCER_TYPE Transducer Type
11 XD_ERROR Transducer Error
12 COLLECTION_
DIRECTORY
Collection Directory
13 PRIMARY_VALUE_TYPE Pressure Type
14 PRIMARY_VALUE Pressure
15 PRIMARY_VALUE_
RANGE
Pressure Range
16 CAL_POINT_HI Calibration Highest Point
17 CAL_POINT_LO Calibration Lowest Point
18 CAL_MIN_SPAN Calibration Minimum Span
19 CAL_UNIT Calibration Units
20 SENSOR_TYPE Sensor Type
21 SENSOR_RANGE Sensor Range
22 SENSOR_SN Sensor Serial Number
23 SENSOR_CAL_
METHOD
Sensor Calibration
method
24 SENSOR_CAL_LOC Sensor Calibration
Location
25 SENSOR_CAL_DATE Sensor Calibration Date
26 SENSOR_CAL_WHO Sensor Calibration Who
27 SENSOR_ISOLATOR_
MTL
Sensor Isolator Metal
28 SENSOR_FILL_FLUID Sensor Fill Fluid
29 SECONDARY_VALUE Static Pres High
Connector
30 SECONDARY_VALUE_
UNIT
Static Pres Unit
31 CAL_DEVIATION_HI Calibration Highest
Deviation
32 CAL_DEVIATION_LO Calibration Lowest
Deviation
33 EXTERNAL_ZERO_TRIM External Zero Trim
34 PRIMARY_VALUE_
FTIME
Pressure Filter Time
35 TERTIARY_VALUE Static Pres Low
Connector
36 SP_VALUE_TYPE Static Pres Type
Relative
Index
Parameter Name Label
37 SP_VALUE_RANGE Static Pres Range
38 CAL_SP_POINT_HI Static Pres Calibration
Highest Point
39 CAL_SP_POINT_LO Static Pres Calibration
Lowest Point
40 CAL_SP_MIN_SPAN Static Pres Calibration
Minimum Span
41 CAL_SP_UNIT Static Pres Calibration
Units
42 CAL_SP_DEVIATION_HI Static Pres Calibration
Highest Deviation
43 CAL_SP_DEVIATION_LO Static Pres Calibration
Lowest Deviation
44 SP_VALUE_FTIME Static Pres Filter Time
45 ATM_PRESS Atmosphere Pressure
46 CURRENT_ATM_
PRESS_ENABLE
One Push Atm Pressure
Enabled
47 EXT_TEMP_VAL Ext Temp
48 EXT_TEMP_RANGE Ext Temp Range
49 CAL_EXT_TEMP_
POINT_HI
Ext Temp Calibration
Highest Point
50 CAL_EXT_TEMP_
POINT_LO
Ext Temp Calibration
Lowest Point
51 CAL_EXT_TEMP_MIN_
SPAN
Ext Temp Calibration
Minimum Span
52 CAL_EXT_TEMP_UNIT Ext Temp Calibration Units
53 CAL_EXT_TEMP_
DEVIA_TION_HI
Ext Temp Calibration
Highest Deviation
54 CAL_EXT_TEMP_
DEVIA_TION_LO
Ext Temp Calibration
Lowest Deviation
55 EXT_TEMP_VALUE_
FTIME
Ext Temp Filter Time
56 EXT_TEMP_OPTS Fixed Mode
57 FIXED_EXT_TEMP_
VALUE
Ext Temp at Fixed Mode
58 SIMULATE_MODE Simulation Mode
59 SIMULATE_DPRESS Simulation Pres
60 SIMULATE_SPRESS Simulation Static Pres
61 SIMULATE_ETEMP Simulation Ext Temp
62 EXT_TEMP_SENSOR_
SN
Ext Temp Sensor Serial
Number
63 CLEAR_CAL Clear Calibration
64 CAP_TEMP_VAL Cap Temp
65 CAP_TEMP_RANGE Cap Temp Range
66 AMP_TEMP_VAL Amp Temp
67 AMP_TEMP_RANGE Amp Temp range
68 MODEL Model
69 SPECIAL_ORDER_ID Special Order ID
70 MANUFAC_DATE Manufacture Date
71 CAP_GASKET_MTL Capsule Gasket Material
72 FLANGE_MTL Flange Material
73 D_VENT_PLUG Drain Vent Plug
74 FLANGE_TYPE Flange Type
75 REM_SEAL_ISOL_MTL Remote Seal Isolator
Material
76 FLANGE_SIZE Flange Size
77 REM_SEAL_NUM Remote Seal Number
78 REM_SEAL_FILL_FLUID Remote Seal Fill Fluid
79 REM_SEAL_TYPE Remote Seal Type
80 ALARM_SUM Alarm Summary
81 AUTO_RECOVERY Auto Recovery