Manual
<9. Parameter Lists>
9-11
IM 01C25R03-01E
Relative
Index
Index Parameter Name Factory Default
Write
Mode
Explanation
52 2552 DISPLAY_UNIT6 Null O/S User specied unit to be displayed on display6, which will be
available when "Custom" is selected at UNIT SEL6.
53 2553 EXP_MODE6 0 O/S Selection of the displayed value in exponent such as x1, x10,
x100, and x1000.
54 2554 BLOCK_TAG7 Null — Block tag which includes a parameter to be displayed on
display7.
55 2555 PARAMETER_SEL7 4208 O/S Selection of a parameter to be displayed on display7.
Select a parameter from Table 6.1
56 2556 DISPLAY_TAG7 Null O/S Name of block tag to be displayed on display7; up to six
alphanumeric plus a slash [/] and a period [.]
57 2557 UNIT_SEL7 0 (Auto) O/S Selection of unit to be displayed. The unit of the parameter
which is selected at PARAMETER SEL7 will be displayed when
"Auto" is selected; user-specied unit at DISPLAY UNIT7 will be
displayed when "Custom" is selected.
58 2558 DISPLAY_UNIT7 Null O/S User specied unit to be displayed on display7, which will be
available when "Custom" is selected at UNIT SEL7.
59 2559 EXP_MODE7 0 O/S Selection of the displayed value in exponent such as x1, x10,
x100, and x1000.
60 2560 BLOCK_TAG8 Null — Block tag which includes a parameter to be displayed on
display8.
61 2561 PARAMETER_SEL8 2035 O/S Selection of a parameter to be displayed on display8.
Select a parameter from Table 6.1
62 2562 DISPLAY_TAG8 Null O/S Name of block tag to be displayed on display8; up to six
alphanumeric plus a slash [/] and a period [.]
63 2563 UNIT_SEL8 0 (Auto) O/S Selection of unit to be displayed. The unit of the parameter
which is selected at PARAMETER SEL8 will be displayed when
"Auto" is selected; user-specied unit at DISPLAY UNIT8 will be
displayed when "Custom" is selected.
64 2564 DISPLAY_UNIT8 Null O/S User specied unit to be displayed on display8, which will be
available when "Custom" is selected at UNIT SEL8.
65 2565 EXP_MODE8 0 O/S Selection of the displayed value in exponent such as x1, x10,
x100, and x1000.
66 2566 BLOCK_TAG9 Null — Block tag which includes a parameter to be displayed on
display9.
67 2567 PARAMETER_SEL9 2064 O/S Selection of a parameter to be displayed on display9.
Select a parameter from Table 6.1
68 2568 DISPLAY_TAG9 Null O/S Name of block tag to be displayed on display9; up to six
alphanumeric plus a slash [/] and a period [.]
69 2569 UNIT_SEL9 0 (Auto) O/S Selection of unit to be displayed. The unit of the parameter
which is selected at PARAMETER SEL9 will be displayed when
"Auto" is selected; user-specied unit at DISPLAY UNIT9 will be
displayed when "Custom" is selected.
70 2570 DISPLAY_UNIT9 Null O/S User specied unit to be displayed on display9, which will be
available when "Custom" is selected at UNIT SEL9.
71 2571 EXP_MODE9 0 O/S Selection of the displayed value in exponent such as x1, x10,
x100, and x1000.
72 2572 BLOCK_TAG10 Null — Block tag which includes a parameter to be displayed on
display10.
73 2573 PARAMETER_SEL10 2314 O/S Selection of a parameter to be displayed on display10.
Select a parameter from Table 6.1
74 2574 DISPLAY_TAG10 Null O/S Name of block tag to be displayed on display10; up to six
alphanumeric plus a slash [/] and a period [.]
75 2575 UNIT_SEL10 0 (Auto) O/S Selection of unit to be displayed. The unit of the parameter
which is selected at PARAMETER SEL10 will be displayed
when "Auto" is selected; user-specied unit at DISPLAY UNIT10
will be displayed when "Custom" is selected.
76 2576 DISPLAY_UNIT10 Null O/S User specied unit to be displayed on display10, which will be
available when "Custom" is selected at UNIT SEL10.
77 2577 EXP_MODE10 0 O/S Selection of the displayed value in exponent such as x1, x10,
x100, and x1000.