6.3.3  Functions Relating to Differential 
Pressure
Reference to differential pressure value:
By accessing PRIMARY_VALUE, it is possible to 
refer to the differential pressure value and status. 
The update period of this value is 200 mseconds. 
The pressure unit is selected by XD_SCALE.
unit of the AI block, in which PRIMARY_VALUE is 
selected. The status is normally Good-Non Specic. 
However, in the case of a sensor failure or out of 
measurement range, it turns to Bad or Uncertain. 
For details, refer to Table 8.9. 
Setting of signal damping for differential 
pressure:
When the differential pressure signal uctuates 
greatly, the uctuation can be reduced by increasing 
the time constant for signal damping. PRIMARY_
VALUE_FTIME is the parameter for setting the 
signal damping for differential pressure. The unit of 
signal damping is second.
Determination of the range limit of differential 
pressure signal:
When the differential pressure signal deviates more 
than 10% from the capsule measurement range 
shown in PRIMARY_VALUE_RANGE, set the 
status of PRIMARY_VALUE to Uncertain-Sensor 
Conversion not Accurate.
Adjustment of pressure/differential pressure 
signal:
EJX multivariable transmitter have been accurately 
adjusted according to the specications at factory 
setting. Minimal errors can occur due to the 
environment where the transmitter is installed and 
the mounting position. To ne-tune any errors, 
three zero/span adjustment functions can be used: 
automatic and manual zero/span adjustment 
by communication terminals, and zero-point 
adjustment by means of the external adjustment 
screw on the transmitter.
Automatic adjustment
The value of the pressure exerted on the point 
where the adjustment is to be made is assigned 
to parameters (CAL_POINT_LO, CAL_POINT_
HI).  After this assignment is set, the amount of 
adjustment is calculated by the transmitter and 
automatically updated.
Manual adjustment
From the exerted pressure and the output of the 
transmitter, calculate the amount of zero/span 
adjustment manually, and assign the calculated 
value to parameters (CAL_DEVIATION_LO, 
CAL_DEVIATION_HI).
Zero-point adjustment by the external screw.
With pressure being exerted on the point where 
the adjustment is to be made, zero adjustment 
needs to be performed. To do this, adjust the 
calculated value by turning the external Zero-point 
adjustment screw, so that it agrees with the actual 
input pressure (true value). The output value 
increases when the screw is rotated to the right. It 
decreases when the screw is rotated to the left. The 
adjustment width is small when the rotation speed 
is low and large when fast.
When performing zero-point adjustment by the 
external screw, EXTERNAL_ZERO_TRIM needs to 
be set to “Enable.” 
Procedure for automatic adjustment
The procedure for automatic adjustment is as 
follows:
F0603.ai
(1) Change the Block mode
Set MODE_BLK to O/S.
(2) Enter zero% pressure
Apply the actual zero% pressure to EJX multivariable 
transmitter.
(6) Change the operation mode
Set MODE_BLK to AUTO for normal operation.
(3) Perform zero adjustment
When the value of the applied pressure is written to 
CAL_POINT_LO, EJX calculates the amount of 
adjustment for zero adjustment. The calculated amount 
of adjustment is incorporated into CAL_DEVIATION_LO.
(5) Performance of span adjustment
When the value of the applied pressure is written to 
CAL_POINT_HI, EJX multivariable transmitter calculates 
the amount of adjustment for span adjustment. The 
calculated amount of adjustment is incorporated into 
CAL_DEVIATION_HI.
(4) Input pressure for span adjustment
For span adjustment, apply the actual 100% pressure to 
EJX multivariable transmitter.