Instruction Manual
<10. General Specications>
10-8
IM 01C27H01-01E
II. Diaphragm seal section (Flush type)
Process connection size: 1 1/2-inch (40 mm)
T11E.ai
Model
EJX118B
EJX438B
Description
Transmitter body section (I)
Flush typeProcess connection style
JIS 10K
JIS 20K
JIS 40K
ANSI class 150
ANSI class 300
ANSI class 600
JPI class 150
JPI class 300
JPI class 600
1 1/2-inch (40 mm)
JIS S25C
JIS SUS304
JIS SUS316
Serration (for ANSI flange only)
Flat (no serration)
[Diaphragm] [Others]
JIS SUS316L JIS SUS316L
[Ring] [Drain/Vent plugs] [Material]
Reducer type R 1/4 connections
*4
JIS SUS316
#
Reducer type 1/4 NPT connections JIS SUS316
#
Reducer type R 1/4 connections
*4
JIS SUS316
#
Reducer type 1/4 NPT connections JIS SUS316
#
None
[Process temp.] [Ambient tempe.]
For general use (silicone oil) –10 to 250°C –10 to 60°C
For general use (silicone oil) –30 to 180°C –15 to 60°C
For oil-prohibited use (fluorinated oil)
*3
–20 to 120°C –10 to 60°C
For low temperature use (ethylene glycol) –50 to 100°C –40 to 60°C
Side of diaphragm seal unit
Always 2
1 m
2 m
3 m
4 m
5 m
6 m
7 m
8 m
9 m
10 m
Flange rating
Process connection size
(Process flange size)
Flange material
►
Gasket contact surface
*1
Wetted parts material
*5
Flushing connection ring
*2
Extension
Fill fluid
►
Capillary connection
Option codes
—
Capillary length
Suffix codes
J1 . . . . . . . . . . . . . . . . .
J2 . . . . . . . . . . . . . . . . .
J4 . . . . . . . . . . . . . . . . .
A1 . . . . . . . . . . . . . . . . .
A2 . . . . . . . . . . . . . . . . .
A4 . . . . . . . . . . . . . . . . .
P1 . . . . . . . . . . . . . . . . .
P2 . . . . . . . . . . . . . . . . .
P4 . . . . . . . . . . . . . . . . .
A . . . . . . . . . . . . . . .
B . . . . . . . . . . . . . . .
C . . . . . . . . . . . . . . .
1 . . . . . . . . . . . . . .
2 . . . . . . . . . . . . . .
3 . . . . . . . . . . . .
4 . . . . . . . . . . . .
C . . . . . . . . . . . .
D . . . . . . . . . . . .
1 . . . . .
2 . . . . .
3 . . . . .
4 . . . . .
5 . . . . .
6 . . . . .
7 . . . . .
8 . . . . .
9 . . . . .
A . . . . .
-A . . . . . . . . .
-B . . . . . . . . .
-D . . . . . . . . .
-E . . . . . . . . .
SW . . . . . . . . . . .
8 . . . . . . . . . . . . . . . . .
0 . . . . . . . . . . .
A . . . . . . . .
2 . . . . . . .
-W . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . .
EJX118B
EJX438B
–
–
–
–
F08E.EPS
EJX118B
EJX438B
W
8
/ Optional specification
The “►” marks indicate the most typical selection for each specication. Example: EJX118B-LMSCG-97JDN-WA18B1SW40-BA25/□
EJX438B-LASCG-97JDN-WA18B1SWD0-BA25/□
*1: See table 10-3 ‘Gasket contact surface.’
*2: When specied ushing connection ring code 3, 4, C, or D, exclusive gasket is provided for transmitter side.
*3: Even in case where ll uid code D (uorinated oil) is selected, if degrease cleansing treatment or both degrease cleansing and
dehydrating treatment for the wetted parts is required, specify option code K1 or K5.
*4: Not applicable for gasket contact surface code 1.
*5: Users must consider the characteristics of selected wetted parts material and the inuence of process uids. The use of
inappropriate materials can result in the leakage of corrosive process uids and cause injury to personnel and/or damage to plant
facilities. It is also possible that the diaphragm itself can be damaged and that material from the broken diaphragm and the ll uid
can contaminate the user’s process uids.
Be very careful with highly corrosive process uids such as hydrochloric acid, sulfuric acid, hydrogen sulde, sodium hypochlorite,
and high-temperature steam (150˚C [302˚F] or above). Contact Yokogawa for detailed information of the wetted parts material.