Instruction Manual
    <10.  General Specications>
10-5
IM 01C27H01-01E
10.2  Model and Sufx Codes
  Instruction
The model and sufx codes for EJX118B and EJX438B consist of two parts; a transmitter body section (I) and 
a diaphragm seal section (II). This specication sheet introduces these two parts separately. The transmitter 
body section is shown in one table, and the diaphragm seal section specications are listed according to the 
process connection style. First select the model and sufx codes of transmitter body section and then continue 
on one of the diaphragm seal section.
F03E.ai
I Transmitter body section II Diaphragm seal section
EJX118B
EJX438B
I. Transmitter body section
T09E.ai
Model
EJX118B
EJX438B
 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
 Diaphragm sealed differential pressure transmitter
 Diaphragm sealed Gauge Pressure transmitter 
Description
 Wireless communication (ISA100.11a protocol)
Output signal
Always S
ASTM-B7 carbon steel
316L SST stainless steel
ASTM grade660 stainless steel
2 to 100 kPa (8 to 400 inH
2
O)
10 to 500 kPa (40 to 200 inH
2
O)
0.035 to 3.5 MPa (5 to 500 psi)
0. 16 to 16 MPa (23 to 2300 psi)
*1
Horizontal piping type and left side high pressure
Cast aluminum alloy with integral antenna
Cast aluminum alloy with detachable antenna (2 dBi)*
5
Cast aluminum alloy without antenna (N connector)*
4
*
5
304 SST 2-inch pipe mounting, flat type (for horizontal piping)
None
Digital indicator
—
Coverflange bolts and nuts material
Installation
Amplifier housing
Mounting braket
 ►
Diaphragm seal section
Integral Indicator
Suffix codes
 - L. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
J . . . . . . . . . . . . . . . . . . . . . .
G . . . . . . . . . . . . . . . . . . . . . . 
C . . . . . . . . . . . . . . . . . . . . . . 
D . . . . . . . . . . .
-9 . . . . . . . . . . . . . . . . . . .
S . . . . . . . . . . . . . . . . . . . . . . . . . . . . 
Always C
—
C . . . . . . . . . . . . . . . . . . . . . . . . .
EJX118B
EJX438B
Continued on diaphragm seal section (II)
7 . . . . . . . . . . . . . . . . .
8 . . . . . . . . . . . . . . . . .
9 . . . . . . . . . . . . . . . . .
B . . . . . . . .
N . . . . . . . .
Measurement span
(capsule)
M
*2
 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
H
*2
 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
A
*3
 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 
B
*3
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
No electrical connection, battery-powered type (battery case only; battery cells 
not included)
J . . . . . . . . . . . . . .
Electrical connection
The “►” marks indicate the most typical selection for each specication.
*1:  When specied process connection style code E, maximum range and span are 7 MPa (1000 psi.)
*2:  Applicable for EJX118B
*3:  Applicable for EJX438B
*4:  Order the antenna separately from accessary option.
*5:  Remote antenna cables can be attached. Order separately from accessary option.