This chapter provides important information on how 
to handle the transmitter. Read this carefully before 
using the transmitter. 
EJX Series transmitters are thoroughly tested at the 
factory before shipment. When taking delivery of an 
instrument, visually check them to make sure that 
no damage occurred during shipment. 
Also check that all transmitter mounting hardware 
shown in gure 2.1 is included. If the transmitter 
is ordered without the mounting bracket and the 
process connector, the transmitter mounting 
hardware will not be included. After checking the 
transmitter, carefully repack it in its box and keep it 
there until you are ready to install it.
Spacer
Mounting bracket
(Flat type)
F0201.ai
U-bolt nut
Transmitter
mounting bolt
U-bolt
The antenna is a detachable 
type when Amplifier housing 
code 8 is selected, and no 
antenna is provided for 
Amplifier housing code 9.
Antenna
Figure 2.1  Transmitter Mounting Hardware
2.1  Model and Specications 
Check
The model name and specications are written on 
the name plate attached to the case.
: Refer to USER'S MANUAL.
Made in Japan
TOKYO 180-8750 JAPAN
MODEL
SUFFIX
SUPPLY
OUTPUT
MWP
mA DC
V DC
STYLE
CAL
RNG
NO.
F0202.ai
Figure 2.2  Name Plate
2.2  Unpacking
Keep the transmitter in its original packaging to 
prevent it from being damaged during shipment. 
Do not unpack the transmitter until it reaches the 
installation site.
2.3  Storage
The following precautions must be observed when 
storing the instrument, especially for a long period.
(a)  Select a storage area which meets the following 
conditions:
•  It is not exposed to rain or subject to water 
seepage/leaks.
•  Vibration and shock are kept to a minimum.
•  It has an ambient temperature and relative 
humidity within the following ranges.
Ambient temperature: 
  –40 to 85°C
  –30 to 80°C LCD visible range
Relative humidity: 
  0% to 100% R.H. 
Preferred temperature and humidity: 
  approx. 25°C and 65% R.H.
(b)  When storing the transmitter, repack it carefully in 
the packaging that it was originally shipped with.
(c) If the transmitter has been used, thoroughly 
clean the chambers inside the cover anges, so 
that there is no process uid remaining inside. 
Before placing it in storage, also make sure that 
the pressure-detector is securely connected to 
the transmitter section.
(d)  Preferably remove the batteries for storage. For 
maximum battery life, the storage temperature 
should not exceed 30°C.
NOTE
When storing the instrument with a battery 
pack, it is recommended to put the instrument in 
Deep Sleep mode to conserve the batteries. For 
details on how to switch to Deep Sleep mode, 
refer to subsection 8.3.16 “Switching to Deep 