    <9.  Parameter Lists>
9-6
IM 01C25T04-01EN
Relative 
Index
Index Parameter
Write 
Mode
Initial Value Explanation
176 192 TEST_16 — — Not used for the transmitter
177 193 TEST_17 — — Not used for the transmitter
178 194 TEST_18 — — Not used for the transmitter
179 195 TEST_19 — — Not used for the transmitter
180 196 TEST_20 — — Not used for the transmitter
181 197 TEST_21 — — Not used for the transmitter
182 198 TEST_22 — — Not used for the transmitter
183 199 TEST_23 — — Not used for the transmitter
184 200 TEST_24 — — Not used for the transmitter
185 201 TEST_25 — — Not used for the transmitter
186 202 TEST_26 — — Not used for the transmitter
187 203 TEST_27 — — Not used for the transmitter
188 204 TEST_28 — — Not used for the transmitter
189 205 TEST_29 — — Not used for the transmitter
190 206 TEST_30 — — Not used for the transmitter
191 207 TEST_31 — — Not used for the transmitter
9.3  LCD Transducer Block
Relative 
Index
Index Parameter
Write 
Mode
Valid 
Range
Initial Value Explanation
0 16 BLOCK_OBJECT — — — Information on this block such as Block Tag, DD 
Revision, Executiion Time etc.
1 17 ST_REV — 0 The revision level of the static data associated 
with the function block. The revision value will be 
incremented each time a static parameter value in 
the block is changed.
2 18 TAG_DESC AUTO Space The user description of the intended application of 
the block.
3 19 STRATEGY AUTO 0-65535 0 The strategy eld can be used to identify grouping 
of blocks. This data is not checked or processed by 
the block.
4 20 ALERT_KEY AUTO 0-255 0 The identication number of the plant unit. This 
information may be used in the host for sorting 
alarms, etc.
5 21 TARGET_MODE AUTO AUTO Set the Target of block mode (MODE_BLK) to Auto, 
Man or O/S according to the write Mode of the 
parameter to be set or changed.
6 22 MODE_BLK — — AUTO The mode parameter is a structured parameter 
composed of the actual mode, the normal mode, 
and the permitted mode.
7 23 ALARM_SUM — — — The current alarm status associated with the 
function block
8 24 DISPLAY_SEL AUTO 0x00-0x0F 0x01 
(DISPLAY1 
ON)
Selection of display 1 to 4 to be shown on LCD
Bit0=1:DISPLAY1 ON
Bit1=1:DISPLAY2 ON
Bit2=1:DISPLAY3 ON
Bit3=1:DISPLAY4 ON
9 25 INFO_SEL AUTO 0x00-0x0F 0x06 Selection of items to be displayed
Bit0=1:TAG ON
Bit1=1:PARAMETER ON
Bit2=1:UNIT ON
Bit3=1:STATUS ON
10 26 BLOCK_TAG1 — — AI1  Block tag which includes a parameter to be 
displayed on display1
11 27 PARAMETER_SEL1 AUTO — 0x010A: AI1.
OUT
Selection of a parameter to be displayed on 
display1. Select a parameter from Table 
12 28 DISPLAY_TAG1 AUTO Space Name of block tag to be displayed on display1; up to 
six alphanumeric plus a slash[/] and a period [.]