User guide
i
IM 01C25F01-01E
Revision Information
Title : Absolute Pressure and Gauge Pressure Transmitters
EJ510, EJ530, EJX610A and EJX630A
Manual No. : IM 01C25F01-01E
Edition Date Page Revised Item
1st Aug. 2004 — New publication.
2nd Feb. 2005 — Re-number gure and table title.
— 2. Revise words and phrases.
2-3 2.9.1 • Add 'a. FM Intrinsically safe Approval.'
2-5 • Add 'c. FM Intrinsically safe/FM Explosionproof Type.'
2-5 2.9.2 • Add subsection '2.9.2 CSA Certication.'
2-7 2.9.3(1) • Add 'a. CENELEC ATEX (KEMA) Intrinsically safe Type.'
2-8 • Correct number in Note 4. 10 MINUTES → 5 MINUTES
• Add 'c. CENELEC ATEX (KEMA) Intrinsically safe Type/
CENELEC ATEX(KEMA) Flameproof Type/CENELEC ATEX
Type n.'
3-1 3. • Add descriptions in Note 2.
4-2 4.4 • Add subsection 4.4.
7-1 7.1 • Delete unnecessary description.
8-4 8.4.2 • Correct calbe color in 1). black → white
8-5 8.4.3 • Add description about stopper in 1).
9-1 to 9-5 9. • Add notes for FOUNDATION eldbus communication type.
9-1 9.1 • Correct Span & Range Limits.
• Correct Burst Pressure Limits.
9-5 9.3 • Add codes for CSA approval and note *3.
3rd July 2006 2-3 to 2-10 • Add/change applicable standards.
2-6 2.9.2 • Add descriptions for Note 2.
2-11 2.10 • Change reference number for Australian standard.
2-11 2.11 • Add descriptions for European Pressure Equipment Directive.
2-12 • Add "2.12 Low Voltage Directive."
9-3 9.1 • Add descriptions for stainless steel housing.
9-4 9.2 • Add amplier housing code 2.
9-5 9.3 • Add code of /SU2.
9-6 9.3 • Add code of /PE3.
4th Feb. 2008 — Change of the style code.
General • Change the gure of amplier housing.
1-1 1 • Add style code table.
2-1 2.1 • Update the Figure 2.2.
2-5 2.9.1 • Add code /V1U.
2-6 2.9.2 • Revise information for CSA Explosionproof type.
2-7 2.9.2 • Add code /V1U.
2-7 to 2-8 2.9.3 • Revise information for KEMA ameproof type. Add code /V1U.
2-9 2.9.3 • Revise Figure in (2) Electrical connection and (6) Nameplate.
2-10 2.9.4 • Revise information for IECEx ameproof type.
9-3 9.1 • Revise weight information.
9-4 9.2 • Add new sufx codes for 316 SST blind plugs and brackets.
9-5 9.3 • Remove /KF2 and /KU2. Add /KF21, /KU21, /SF2 and /V1U.
9-6 • Add /HC.
9-7 9.4 • Revise external dimensions.
5th Aug. 2009 2.1 2.1 • Replace a name plate.
2-6 2.9.2 • Correct certicate No. for CSA explosionproof type.
2-10 2.10 • Revise standards.
2-11 to 2-12 2.11 • Revise information of PED.
9-5 9.3 • Add process sealing statement for CSA approval.
9-6 9.3 • Add /A1, and /DG6.