User guide

<9. General Specications>
9-6
IM 01C25F01-01E
Model Sufx Codes Description
EJX610A
EJX630A
. . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . .
Absolute pressure transmitter
Gauge pressure transmitter
Output
signal
-D . . . . . . . . . . . . . . . . . . . .
-E . . . . . . . . . . . . . . . . . . . .
-F . . . . . . . . . . . . . . . . . . . .
-G . . . . . . . . . . . . . . . . . . . .
4 to 20 mA DC Output with digital communication (BRAIN protocol)
4 to 20 mA DC Output with digital communication (HART protocol)
Digital communication (FOUNDATION Fieldbus protocol,
refer to IM 01C25T02-01E)
Digital communication (PROFIBUS PA protocol,
refer to IM 01C25T04-01EN)
Measurement
span (capsule)
A. . . . . . . . . . . . . . . . . . .
B. . . . . . . . . . . . . . . . . . .
C. . . . . . . . . . . . . . . . . . .
D. . . . . . . . . . . . . . . . . . .
2 to 200 kPa (0.3 to 29 psi)
0.01 to 2 MPa (1.5 to 290 psi)
0.05 to 10 MPa (7.3 to 1450 psi)
0.35 to 70 MPa (50.8 to 10150 psi)
Wetted parts
material *
4
S . . . . . . . . . . . . . . . . . .
H. . . . . . . . . . . . . . . . . .
Process connection Diaphragm
316L SST
#
Hastelloy C-276
*1 #
Hastelloy C-276
*1 #
Hastelloy C-276
*1 #
Process
connections
4 . . . . . . . . . . . . . . . .
7 . . . . . . . . . . . . . . . .
8 . . . . . . . . . . . . . . . .
9 . . . . . . . . . . . . . . . .
1/2 NPT female
1/2 NPT male
G1/2 DIN 16 288 male *
2
M21.5 DIN 16 288 male *
2
N. . . . . . . . . . . . . . Always N
-0 . . . . . . . . . . .
Always 0
Amplier housing 1 . . . . . . . . . .
2 . . . . . . . . . .
3 . . . . . . . . . .
Cast aluminum alloy
ASTM CF-8M Stainless Steel *
5
Cast aluminum alloy with corrosion resistance properties
Electrical connection
0 . . . . . . . . .
2 . . . . . . . . .
4 . . . . . . . . .
5 . . . . . . . . .
7 . . . . . . . . .
9 . . . . . . . . .
A. . . . . . . . .
C. . . . . . . . .
D. . . . . . . . .
G1/2 female, one electrical connection without blind plugs
1/2 NPT female, two electrical connections without blind plugs
M20 female, two electrical connections without blind plugs
G1/2 female, two electrical connections with a blind plug *
6
1/2 NPT female, two electrical connections with a blind plug *
6
M20 female, two electrical connections with a blind plug *
6
G1/2 female, two electrical connections and a 316 SST blind plug
1/2 NPT female, two electrical connections and a 316 SST blind plug
M20 female, two electrical connections and a 316 SST blind plug
Integral indicator
D. . . . . . .
E . . . . . . .
N. . . . . . .
Digital indicator
*7
Digital indicator with the range setting switch *
3
None
Mounting bracket
F . . . . .
L . . . . .
N. . . . .
304 SST 2-inch pipe mounting
316 SST 2-inch pipe mounting
None
Optional codes
/ Optional specication
The “►” marks indicates the most typical selection for each specication. Example: EJX630A-DAS4N-012NN/.
*1: Hastelloy C-276 or ASTM N10276.
*2: Not applicable for combination of capsule code D and wetted parts material code H.
*3: Not applicable for output signal code F.
*4: Users must consider the characteristics of selected wetted parts material and the inuence of process uids. The use of
inappropriate materials can result in the leakage of corrosive process uids and cause injury to personnel and/or damage to plant
facilities. It is also possible that the diaphragm itself can be damaged and that material from the broken diaphragm and the ll uid
can contaminate the user’fs process uids.
Be very careful with highly corrosive process uids such as hydrochloric acid, sulfuric acid, hydrogen sulde, sodium hypochlorite,
and high-temperature steam (150°C [302°F] or above). Contact Yokogawa for detailed information of the wetted parts material.
*5: Not applicable for electrical connection code 0, 5, 7 or 9.
*6: Material of a blind plug is aluminum alloy or 304 SST.
*7: Not applicable for output signal code G.
# The ‘#’ marks indicate the construction materials conform to NACE material recommendations per MR01-75. For the use of 316
SST material, there may be certain limitations for pressure and temperature. Please refer to NACE standards for details.