9. General Specications
9.1 Standard Specications
Refer to IM 01C25T02-01E for FOUNDATION
Fieldbus communication type and IM 01C25T04-
01EN for PROFIBUS PA communication type for
the items marked with “◊”.
Performance Specications
See General Specications sheet for each model.
Functional Specications
Span & Range Limits
EJX530A
Measurement
Span/Range
MPa psi(/D1) bar(/D3) kgf/cm
2
(/D4)
A
Span
8 to 200kPa 1.16 to 29 0.08 to 2 0.08 to 2
Range
-100 to
200 kPa
-14.5 to 29 -1 to 2 -1 to 2
B
Span
0.04 to 2 5.8 to 290 0.4 to 20 0.4 to 20
Range
-0.1 to 2 -14.5 to 290 -1 to 20 -1 to 20
C
Span
0.2 to 10 29 to 1450 2 to 100 2 to 100
Range
-0.1 to 10 -14.5 to 1450 -1 to 100 -1 to 100
D
Span
1 to 50 145 to 7200 10 to 500 10 to 500
Range
-0.1 to 50 -14.5 to 7200 -1 to 500 -1 to 500
EJX510A (Values are absolute pressure)
Measurement
Span/Range
MPa psi(/D1) bar(/D3) kgf/cm
2
(/D4)
A
Span
8 to 200 kPa 1.16 to 29 0.08 to 2 0.08 to 2
Range
0 to 200 kPa 0 to 29 0 to 2 0 to 2
B
Span
0.04 to 2 5.8 to 290 0.4 to 20 0.4 to 20
Range
0 to 2 0 to 290 0 to 20 0 to 20
C
Span
0.2 to 10 29 to 1450 2 to 100 2 to 100
Range
0 to 10 0 to 1450 0 to 100 0 to 100
D
Span
1 to 50 145 to 7200 10 to 500 10 to 500
Range
0 to 50 0 to 7200 0 to 500 0 to 500
EJX630A
Measurement
Span/Range
MPa psi (/D1) bar (/D3)
kgf/cm
2
(/D4)
A
Span
2 to 200 kPa 0.3 to 29 0.02 to 2 0.02 to 2
Range
-100 to 200
kPa
-14.5 to 29 -1 to 2 -1 to 2
B
Span
0.01 to 2 1.5 to 290 0.1 to 20 0.1 to 20
Range
-0.1 to 2 -14.5 to 290 -1 to 20 -1 to 20
C
Span
0.05 to 10 7.3 to 1450 0.5 to 100 0.5 to 100
Range
-0.1 to 10 -14.5 to 1450 -1 to 100 -1 to 100
D
Span
0.35 to 70
50.8 to
10150
3.5 to 700 3.5 to 700
Range
-0.1 to 70
-14.5 to
10150
-1 to 700 -1 to 700
EJX610A (Values are absolute pressure)
Measurement
Span/Range
MPa psi (/D1) bar (/D3)
kgf/cm
2
(/D4)
A
Span
2 to 200 kPa 0.3 to 29 0.02 to 2 0.02 to 2
Range
0 to 200 kPa 0 to 29 0 to 2 0 to 2
B
Span
0.01 to 2 1.5 to 290 0.1 to 20 0.1 to 20
Range
0 to 2 0 to 290 0 to 20 0 to 20
C
Span
0.05 to 10 7.3 to 1450 0.5 to 100 0.5 to 100
Range
0 to 10 0 to 1450 0 to 100 0 to 100
D
Span
0.35 to 70
50.8 to
10150
3.5 to 700 3.5 to 700
Range
0 to 70 0 to 10150 0 to 700 0 to 700
EJA530E
Measurement
Span/Range
MPa psi(/D1) bar(/D3) kgf/cm
2
(/D4)
A
Span
10 to 200
kPa
1.45 to 29 0.1 to 2 0.1 to 2
Range
-100 to
200 kPa
-14.5 to 29 -1 to 2 -1 to 2
B
Span
0.1 to 2 14.5 to 290 1 to 20 1 to 20
Range
-0.1 to 2 -14.5 to 290 -1 to 20 -1 to 20
C
Span
0.5 to 10 72.5 to 1450 5 to 100 5 to 100
Range
-0.1 to 10 -14.5 to 1450 -1 to 100 -1 to 100
D
Span
5 to 50 720 to 7200 50 to 500 50 to 500
Range
-0.1 to 50 -14.5 to 7200 -1 to 500 -1 to 500
EJA510E (Values are absolute pressure)
Measurement
Span/Range
MPa psi(/D1) bar(/D3) kgf/cm
2
(/D4)
A
Span
10 to 200
kPa
1.45 to 29 0.1 to 2 0.1 to 2
Range
0 to 200 kPa 0 to 29 0 to 2 0 to 2
B
Span
0.1 to 2 14.5 to 290 1 to 20 1 to 20
Range
0 to 2 0 to 290 0 to 20 0 to 20
C
Span
0.5 to 10 72.5 to 1450 5 to 100 5 to 100
Range
0 to 10 0 to 1450 0 to 100 0 to 100
D
Span
5 to 50 720 to 7200 50 to 500 50 to 500
Range
0 to 50 0 to 7200 0 to 500 0 to 500
Output “◊”
Two wire 4 to 20 mA DC output with digital
communications, linear or square root
programmable. BRAIN or HART FSK protocol
are superimposed on the 4 to 20 mA signal.
Output range: 3.6 mA to 21.6 mA
Output limits conform to NAMUR NE43 can be
pre-set by option C2 or C3.