<5. Parameter Summary>
5-6
IM 01C25T01-06EN
Function Label Item Contents Default value Handling *
1
Fluct Variables fDP Average value of the sum of
squares of differential pressure/
pressure uctuations
RG
fDP Status Status of fDP RG
fSPl Average value of the sum of
squares of low-pressure-sidestatic
pressure uctuations
RG
fSPl Status Status of fSPl RG
fSPh Average value of the sum of
squares of high-pressure-side
static pressure uctuations
RG
fSPh Status Status of fSPh RG
Loop test Loop test Test output setting Within AO lower and upper
limits
M
Test Auto Release
Time
Auto release time for the test
function. Coverage is Loop test,
DO test and Device Variable
Simulation.
10min, 30min, 60min, 3h,
6h, 12h
10 min W
Low cut Low cut Low cut 0.00 to 20.00% Refer to
subsection
3.2.6
W
Low cut mode Low cut mode Linear or Zero Linear W
Master test Master test Software reset and self test M
Message Message Message 32 alphanumerics As specied W
Number of
requested
preambles
Num req preams Number of requested preambles R
Num resp preams
HART 7
Number of response preambles 5 W
Optional
function
Option Password
Optional function activation
password
W
Piping
orientation
H/L Swap Impulse piping accessing direction Normal or Reverse Normal WD
Poll address Poll addr Poll address for multidrop use 0 to 15(HART 5), 0 to
63(HART 7)
0 W
Loop current mode
HART 7
Loop current mode in Multi Drop
mode
(Disabled, Enabled) Disabled W
Process Alerts Digital Output
EJX
Display of contact output Off or On Off RA
DO Select
EJX
Contact output select Off, Combination of Pres, SP
and Temp
Off WA
DO Signal type
EJX
Signal type select ON WHEN AL. DETECT, OFF
WHEN AL. DETECT
ON WHEN AL.
DETECT
WA
DO Test
EJX
Test output contact Status High, Status Low, Exit MA
Pres Alert Mode Alert Mode for differential pressure Off, Hi Al Detect,Lo Al Detect,
Hi/Lo Al Detect
Off W
Hi Alert Val High alert value for differential
pressure
Set the threshold value for
high side alarm
W
Lo Alert Val Low alert value for differential
pressure
Set the threshold value for
low side alarm
W
SP Alert Mode Alert Mode for static pressure Off, Hi Al Detect,Lo Al Detect,
Hi/Lo Al Detect
Off WD
SP Hi Alert Val High alert value for static pressure Set the threshold value for
high side alarm
WD
SP Lo Alert Val Low alert value for static pressure Set the threshold value for
low side alarm
WD
Temp Alert Mode Alert Mode for temperature Off, Hi Al Detect,Lo Al Detect,
Hi/Lo Al Detect
Off W
*1: Handling:
R
=Read only,
W
=Read & Write,
M
=Method,
A
=Applicable for option code AL,
G
=Applicable for option code DG6,
D
=Applicable for differential pressure transmitters. Do not change these parameters for pressure transmitters.
*2: Max three Burst Messages (Burst Message 1, Burst Message 2, Burst Message 3)
*3: The default value shows MWP (Maximum working pressure) of the capsule.
Since the working pressure limit varies according to the Model, refer to the General Specications section in each user’s manual.