User Manual
IM 01C22T02-01E
8-2
8. GENERAL SPECIFICATIONS
8.2 Optional Specifications
For items other than those described below, refer to each User’s Manual.
T0801.EPS
Item Description Code
Factory Mutual (FM)
CENELEC ATEX (KEMA) Flameproof Approval *
2
  Certificate: KEMA 02ATEX2148
  II 2G EEx d IIC T4, T5 and T6, Amb. Temp.: 40 to 80"C (40 to 176"F) for T5, 
  40 to 75"C (40 to 167"F) for T4 and T6
  Max. process Temp.: T4; 120"C (248"F), T5; 100"C (212"F), T6; 85"C (185"F)
  Enclosure: IP67
CENELEC ATEX (KEMA) Type n Approval *
2
    II 3G Ex nL IIC T4, Amb. Temp. –40 to 60°C (–40 to 140"F), Enclosure: IP67
      Ui=32V, Ci=3.52 nF, Li=0µH
CENELEC ATEX (KEMA) Intrinsically Safe Approval *
2
  Certificate: KEMA 02ATEX1344X
  [Entity model]
    II 1G EEx ia IIC T4, Amb. Temp.: 40 to 60"C (40 to 140"F) 
      Ui=24.0 V, Ii=250 mA, Pi=1.2 W, Ci=1.76 nF, Li=0 H
  [FISCO model]
    II 1G EEx ia IIC T4, Amb. Temp.: 40 to 60"C (40 to 140"F) 
      Ui=17.5 V, Ii=360 mA, Pi=2.52 W, Ci=1.76 nF, Li=0 H
    II 1G EEx ia IIB T4, Amb. Temp.: 40 to 60"C (40 to 140"F) 
      Ui=17.5 V, Ii=380 mA, Pi=5.32 W, Ci=1.76 nF, Li=0 H
  Enclosure: IP67
KF25
KN25
KS25
CENELEC ATEX (KEMA)
FF15
FS15
FN15
FM Explosionproof Approval *
1
  Explosionproof for Class I, Division 1, Groups B, C and D 
  Dust-ignitionproof for Class II/III, Division 1, Groups E, F and G
  Hazardous (classified) locations, indoors and outdoors (NEMA 4X)
  Temperature class: T6 Amb. Temp.:–40 to 60°C (–40 to 140°F) 
FM Intrinsically Safe Approval *
1
  [Entity Model]
Cl. I, II&III, Division 1, Groups A, B, C ,D, E, F&G, Temp. Cl. T4 and Cl. I, Zone 0, 
AEx ia IIC, Temp. Cl. T4
Groups A, B, C, D, E, F&G and Group IIC:
      Vmax.= 24 V, Imax.= 250 mA, Pi= 1.2 W, Ci= 3.52 nF, Li= 0 µH
  [FISCO Model]
Cl. I, II&III, Division 1, Groups A, B, C, D, E, F&G, Temp. Cl. T4 and Cl. I, Zone 0, 
AEx ia IIC, Temp. Cl. T4
Groups A, B, C, D, E ,F&G and Group IIC:
  Vmax.= 17.5 V, Imax.= 360 mA, Pi = 2.52 W, Ci = 3.52 nF, Li = 0µH
Groups C, D, E, F&G and Group IIB:
      Vmax.= 17.5V, Imax. = 380 mA, Pi = 5.32W, Ci = 3.52 nF, Li = 0µH
Nonincendive for Cl. I, Division 2, Groups A, B, C&D, Temp. Cl. T4
and Cl. I, Zone 2, Group IIC, Temp. Cl. T4
and Cl. II, Division 2, Groups F&G Temp. Cl. T4
and Cl. III, Division 2, Temp. Cl. T4
  Vmax.= 32 V, Ci = 3.52 nF, Li = 0µH
  Enclosure: “NEMA4X”, Amb. Temp.: –40 to 60°C (–40 to 140"F)
FM Nonincendive Approval for /EE Software download *
1
 *
3
Class I, Division 2, Group A, B, C, & D
Class II, Division 2, Group F & G and Class III, Division 1
Class I, Zone 2, Group IIC in Hazardous (Classified) locations
Enclosure: “NEMA4X”, Temp. Cl.: T4, Amb. Temp. –40 to 60°C (–40 to 140"F)
  Vmax.=32V, Ci=3.52 nF, Li=0µH
IECEx Flameproof Approval *
2
 Certificate: IECEx KEM 06.0005
 Ex d IIC T6...T4 Enclosure: IP67
 Max.Process Temp.: T4;120"C (248"F), T5;100"C (212"F), T6; 85"C (185"F)
 Amb.Temp.: –40 to 75"C (–40 to 167"F) for T4, –40 to 80"C (–40 to 176"F) for T5,
    –40 to 75"C (–40 to 167"F) for T6
SF25
IECEx Scheme
*1: Applicable for Electrical connection code 2 and 7.
*2: Applicable for Electrical connection code 2, 4, 7 and 9.
*3: Applicable for only Option code EE.