Manual
    <2. Handling Cautions>
5
IM 01C22A01-01E
2. Handling Cautions
When the transmitter is delivered, visually check them 
to make sure that no damage occurred during shipment. 
Also check that all transmitter mounting hardware shown 
in Figure 2.1 is included. If the transmitter was ordered 
without the mounting bracket or without the process 
connector, the transmitter mounting hardware is not 
included. 
Table 2.1  Applicable Model Code for Mounting 
Hardware
Applicable 
model
Suffi x code Part name Qty
EJA110A
EJA120A
EJA130A
Process 
connections
1, 2, 3, and 4
Process connector bolt 4
Process connector 2
Process connector 
gasket
2
EJA210A
EJA220A
EJA310A
EJA430A
EJA440A
Process 
connections
1, 2, 3, and 4
Process connector bolt 2
Process connector 1
Process connector 
gasket
1
EJA110A
EJA120A
EJA130A
EJA310A
EJA430A
EJA440A
EJA118
EJA438
EJA115
Mounting bracket 
A, B, C, and D
U-bolt 1
U-bolt nut 2
Mounting bracket 
(L or fl at type)
1
Transmitter mounting 
bolt
4
EJA510A
EJA530A
Mounting bracket 
E and F
U-bolt and nut (L) 1
U-bolt and nut (S) 1
Mounting bracket 
(L or fl at type)
1
Plate 1
Adapter 1
EJA210A
EJA438W
Option code /T
Tefl on fi lm 1
Fluorinated oil 1
EJA118W
Option code /T
Tefl on fi lm 2
Fluorinated oil  2
EJA110A
EJA120A
EJA130A
EJA310A
EJA430A
EJA440A
 - 
1
2
3
4
 - 
A
B
C
D
EJA115 -  - 
A
B
C
D
EJA210A
EJA220A
1
2
3
4
 -  - 
EJA118
EJA438
A
B
 -  -  - 
F0201.ai
EJA510A
EJA530A
E
F
 -  - 
Bolt
Process connector
Process connector
Gasket
U-bolt nut
U-bolt
Mounting bracket
(L type)
Transmitter mounting bolt
Mounting bracket
(Flat type)
F0202.ai
Teflon film
Fluorinated oil
U-bolt nut (S)
Plate
U-bolt nut (L)
U-bolt (L)
Mounting bracket
(Flat type)
Adapter
U-bolt (S)
Figure 2.1  Transmitter Mounting Hardware
2.1  Model and Specifi cations 
Check
The model name and specifi cations are indicated on the 
name plate attached to the case.
F0203.ai
: Refer to USER'S MANUAL
Figure 2.2  Name Plate
2.2  Selecting the Installation 
Location
The transmitter is designed to withstand severe 
environmental conditions. However, to ensure stable 
and accurate operation for years, observe the following 
precautions when selecting an installation location.
(a) Ambient Temperature
Avoid locations subject to wide temperature variations 
or a signifi cant temperature gradient. If the location 
is exposed to radiant heat from plant equipments, 
provide adequate thermal insulation and/or 
ventilation.
Handling Cautions