Manual
    <1. Introduction>
2
IM 01C22A01-01E
CAUTION
Indicates a potentially hazardous situation which, if not 
avoided, may result in minor or moderate injury. It may 
also be used to alert against unsafe practices.
IMPORTANT
Indicates that operating the hardware or software in 
this manner may damage it or lead to system failure.
NOTE
Draws attention to information essential for 
understanding the operation and features.
 Direct current
1.1  For Safe Use of Product
For the protection and safety of the operator and the 
instrument or the system including the instrument, please 
be sure to follow the instructions on safety described 
in this manual when handling this instrument. In case 
the instrument is handled in contradiction to these 
instructions, Yokogawa does not guarantee safety. 
Please give your attention to the followings.
(a) Installation
•  The instrument must be installed by an expert 
engineer or a skilled personnel. The procedures 
described about INSTALLATION are not permitted for 
operators.
•  In case of high process temperature, care should 
be taken not to burn yourself because the surface of 
body and case reaches a high temperature.
•  The instrument installed in the process is under 
pressure. Never loosen the process connector bolts 
to avoid the dangerous spouting of process fl uid.
•  During draining condensate from the pressure 
detector section, take appropriate care to avoid 
contact with the skin, eyes or body, or inhalation of 
vapors, if the accumulated process fl uid may be toxic 
or otherwise harmful.
•  When removing the instrument from hazardous 
processes, avoid contact with the fl uid and the interior 
of the meter.
•  All installation shall comply with local installation 
requirement and local electrical code.
(b) Wiring
•  The instrument must be installed by an expert 
engineer or a skilled personnel. The procedures 
described about WIRING are not permitted for 
operators.
• Please confi rm that voltages between the power 
supply and the instrument before connecting the 
power cables and that the cables are not powered 
before connecting.
(c) Operation
•  Wait 10 min. after power is turned off, before opening 
the covers.
(d) Maintenance
•  Please do not carry out except being written to 
maintenance descriptions. When these procedures 
are needed, please contact nearest YOKOGAWA 
offi ce.
•  Care should be taken to prevent the build up of drift, 
dust or other material on the display glass and name 
plate. In case of its maintenance, soft and dry cloth is 
used.
(e)  Explosion Protected Type Instrument
•  Users of explosion proof instruments should refer fi rst 
to section 2.4 (Installation of an Explosion Protected 
Instrument) of this manual.
•  The use of this instrument is restricted to those who 
have received appropriate training in the device.
•  Take care not to create sparks when accessing the 
instrument or peripheral devices in a hazardous 
location.
(f) Modifi cation
•  Yokogawa will not be liable for malfunctions or 
damage resulting from any modifi cation made to this 
instrument by the customer.
1.2 Warranty
•  The warranty shall cover the period noted on the 
quotation presented to the purchaser at the time of 
purchase. Problems occurred during the warranty 
period shall basically be repaired free of charge.
•  In case of problems, the customer should contact the 
Yokogawa representative from which the instrument 
was purchased, or the nearest Yokogawa offi ce.
•  If a problem arises with this instrument, please inform 
us of the nature of the problem and the circumstances 
under which it developed, including the model 
specifi cation and serial number. Any diagrams, 
data and other information you can include in your 
communication will also be helpful.