    <8. Parameter Summary>
29
IM 01C22A01-01E
8. Parameter Summary
NOTE
For FOUNDATION Fieldbus and PROFIBUS PA 
communication types, please refer to manuals in the 
attached CD-ROM.
IMPORTANT
If the transmitter is turned off within 30 seconds after 
parameters have been set, the set data will not be 
stored and the terminal returns to previous settings.
  HART Communication Menu Tree
1 DEVICE SETUP 
2 Pres 
3 A01 Out 
4 LRV 
5 URV 
Online Menu 
1 PROCESS 
 VARIABLES 
2 DIAGNOSTICS 
 AND SERVICE 
3 BASIC SETUP 
4 DETAILED 
 SETUP 
5 REVIEW 
1 Pressure 
2 Percent Range 
3 Analog Output 
4 Sensor Temperature 
5 Static Pressure 
6 Engineering Unit 
7 Engineering Display 
1 TEST/STATUS 
2 Loop Test 
3 CALIBRATION 
1 Self Test 
2 Status 
1 Keypad Input 
2  Wrt protect menu 
Hot Key  1 LRV 
2 URV 
3 Unit 
4 LSL 
5 USL 
6 Min Span 
1 Tag 
2 Unit 
3 RERANGE 
4 DEVICE INFO 
5 Transfer Function 
6 Damp 
7 Low Cut 
8 Cut Mode 
1 Keypad Input 
2 Apply Values 
1 Date 
2 Descriptor 
3 Message 
4 Write Protect 
1 SENSORS 
2 SIGNAL 
 CONDITION 
3 OUTPUT 
 CONDITION 
4 DISPLAY 
 CONDITION 
5 DEVICE 
 INFORMATION 
1 Pressure Sensor 
2 Temperature 
 Sensor 
3 Static Pressure 
 Sensor 
1 Percent Range 
2 Pressure 
3 Unit 
4 Sensor Trim 
1 Zero Trim
2 Pressure
3 Lower Sensor Trim
4 Upper Sensor Trim
5 Sensor Trim Point
6 Clear snsr trim
1 Snsr temp
2 Amp temp
3 Sensor temp Unit
1 Static Pressure 
2  Static Pressure Unit 
1 PROCESS 
 VARIABLES 
2 RERANGE 
3 Unit 
4 Transfer Function 
5 Damp 
6 Low Cut 
7 Cut Mode 
8 Bi-dir Mode 
9  H2O Unit Select 
1 PROCESS 
 VARIABLES 
2 ANALOG  
 OUTPUT 
3 Analog Output 
 Alarm 
4 HART OUTPUT 
1 Display Mode 
2 Display Function 
3 Engineering 
 Display Range 
1 Field Device Info 
2 Sensor Info 
3 Self Test 
1 Engineering Unit 
2 Engineering Display LRV 
3 Engineering Display URV 
4 Engineering Display Point 
1 Pressure
2 Percent Range
3 Analog Output
4 Sensor Temperature
5 Static Pressure
6 Engineering Unit
7 Engineering Display
1 Loop Test
2 Digital-to-Analog Trim
3 Scaled D/A Trim
4 Auto recover
5 AO lower limit %
6 AO upper limit %
1 Poll Address 
2  Number of Request Preambles 
3 Burst Mode 
4 Burst Option 
1 Pressure 
2 Percent Range 
3 Sensor Temperature 
1 Keypad Input 
2 Apply Values 
1 RERANGE 
2 TRIM ANALOG 
 OUTPUT 
3 SENSOR TRIM 
1 Keypad Input 
2 Apply Values 
1 Digital-to-Analog Trim 
2 Scaled Digital-to-Analog Trim 
1 Zero Trim
2 Pressure
3 Lower Sensor Trim
4 Upper Sensor Trim
5 Sensor Trim Points
6 Clear snsr trim
F0801.ai
1 Write protect
2  Enable wrt 10 min
3 New password
4 Software seal
Errors and Countermeasures
7
Parameter Summary
8